  Datasheet File OCR Text:
  single-phase multifunction metering ic with di/dt sensor interface ade7753 rev. c information furnished by analog devices is believed to be accurate and reliable. however, no responsibility is assumed by analog devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. specifications subject to change without notice. no license is granted by implication or otherwise under any patent or patent rights of analog devices. trademarks and registered trademarks are the property of their respective owners. one technology way, p.o. box 9106, norwood, ma 02062-9106, u.s.a. tel: 781.329.4700 www.analog.com fax: 781.461.3113 ?2003C2010 analog devices, inc. all rights reserved. features high accuracy; supports iec 60687/61036/61268 and iec 62053-21/62053-22/62053-23 on-chip digital integrator enables direct interface to current sensors with di/dt output a pga in the current channel allows direct interface to shunts and current transformers active, reactive, and apparent energy; sampled waveform; current and voltage rms less than 0.1% error in active energy measurement over a dynamic range of 1000 to 1 at 25c positive-only energy accumulation mode available on-chip user programmable threshold for line voltage surge and sag and psu supervisory digital calibration for power, phase, and input offset on-chip temperature sensor (3c typical) spi? compatible serial interface pulse output with programmable frequency interrupt request pin ( irq ) and status register reference 2.4 v with external overdrive capability single 5 v supply, low power (25 mw typical) general description the ade7753 1 features proprietary adcs and dsp for high accuracy over large variations in environmental conditions and time. the ade7753 incorporates two second-order 16-bit - adcs, a digital integrator (on ch1), reference circuitry, temperature sensor, and all the signal processing required to perform active, reactive, and apparent energy measurements, line-voltage period measurement, and rms calculation on the voltage and current. the selectable on-chip digital integrator provides direct interface to di/dt current sensors such as rogowski coils, eliminating the need for an external analog integrator and resulting in excellent long-term stability and pre- cise phase matching between the current and voltage channels. the ade7753 provides a serial interface to read data, and a pulse output frequency (cf), which is proportional to the active power. various system calibration features, i.e., channel offset correction, phase calibration, and power calibration, ensure high accuracy. the part also detects short duration low or high voltage variations. the positive-only accumulation mode gives the option to accumulate energy only when positive power is detected. an internal no-load threshold ensures that the part does not exhibit any creep when there is no load. the zero-crossing output (zx) produces a pulse that is synchronized to the zero-crossing point of the line voltage. this signal is used internally in the line cycle active and apparent energy accumulation modes, which enables faster calibration. the interrupt status register indicates the nature of the interrupt, and the interrupt enable register controls which event produces an output on the irq pin, an open-drain, active low logic output. the ade7753 is available in a 20-lead ssop package. functional block diagram avdd reset dvdd dgnd temp sensor adc adc dfc x 2 ade7753 lpf2 multiplier integrator clkin clkout din dout sclk ref in/out cs irq agnd apos[15:0] vagain[11:0] vadiv[7:0] irmsos[11:0] vrmsos[11:0] wgain[11:0] dt  registers and serial interface cfnum[11:0] cfden[11:0] 2.4v reference 4k phcal[5:0] hpf1 lpf1 02875-a-001 v1p v1n v2n v2p pga pga zx sag cf wdiv[7:0] % % 2 |x| figure 1. 1 u.s. patents 5,745,323; 5,760,617; 5, 862,069; 5,872,469; others pending.
ade7753 rev. c | page 2 of 60 table of contents features .............................................................................................. 1 general description ......................................................................... 1 functional block diagram .............................................................. 1 revision history ............................................................................... 3 specifications ..................................................................................... 4 timing characteristics ..................................................................... 6 absolute maximum ratings ............................................................ 7 esd caution .................................................................................. 7 terminology ...................................................................................... 8 pin configuration and function descriptions ............................. 9 typical performance characteristics ........................................... 11 theory of operation ...................................................................... 16 analog inputs .............................................................................. 16 di/dt current sensor and digital integrator ............................... 17 zero-crossing detection ........................................................... 18 period measurement .................................................................. 19 power supply monitor ............................................................... 19 line voltage sag detection ....................................................... 19 peak detection ............................................................................ 20 ade7753 interrupts ................................................................... 21 temperature measurement ....................................................... 22 ade7753 analog-to-digital conversion ................................ 22 channel 1 adc .......................................................................... 23 channel 2 adc .......................................................................... 25 phase compensation .................................................................. 27 active power calculation .......................................................... 28 energy calculation ..................................................................... 29 power offset calibration ........................................................... 31 energy-to-frequency conversion............................................ 31 line cycle energy accumulation mode ................................. 33 positive-only accumulation mode ......................................... 33 no-load threshold .................................................................... 33 reactive power calculation ...................................................... 33 sign of reactive power calculation ......................................... 35 apparent power calculation ..................................................... 35 apparent energy calculation ................................................... 36 line apparent energy accumulation ...................................... 37 energies scaling .......................................................................... 38 calibrating an energy meter based on the ade7753 ........... 38 clkin frequency ...................................................................... 48 suspending ade7753 functionality ....................................... 48 checksum register..................................................................... 48 ade7753 serial interface .......................................................... 49 ade7753 registers ......................................................................... 52 ade7753 register descriptions ................................................... 55 communications register ......................................................... 55 mode register (0x09) ................................................................. 55 interrupt status register (0x0b), reset interrupt status register (0x0c), interrupt enable register (0x0a) .............. 57 ch1os register (0x0d) ............................................................ 58 outline dimensions ....................................................................... 59 ordering guide .......................................................................... 59
ade7753 rev. c | page 3 of 60 revision history 1/10rev. b to rev c changes to figure 1 ........................................................................... 1 changes to t 6 parameter (table 2) ................................................... 6 added endnote 1 to table 4 ............................................................. 9 changes to figure 32 ...................................................................... 16 changes to period measurement section .................................... 19 changes to temperature measurement section ......................... 22 changes to figure 51 ...................................................................... 24 changes to channel 1 rms calculation section ........................ 25 added table 7 .................................................................................. 25 changes to channel 2 rms calculation section ........................ 26 added table 8 .................................................................................. 26 changes to figure 64 ...................................................................... 29 changes to apparent power calculation section ....................... 35 1/09rev. a to rev b changes to features section ............................................................ 1 changes to zero-crossing detection section and period measurement section ..................................................................... 19 changes to channel 1 rms calculation section, channel 1 rms offset compensation section, and equation 4 ................. 25 changes to figure 56 and channel 2 rms calculation section .............................................................................................. 26 changes to figure 57 ...................................................................... 27 changes to energy calculation section ....................................... 30 changes to energy-to-frequency conversion section .............. 31 changes to apparent energy calculation section...................... 36 changes to line apparent energy accumulation section ........ 37 changes to table 10 ........................................................................ 52 changes to table 12 ........................................................................ 56 changes to table 13 ........................................................................ 57 changes to ordering guide ........................................................... 59 6/04rev. 0 to rev a changes iec standards .................................................................... 1 changes to phase error between channels definition ............... 7 changes to figure 24 ...................................................................... 13 changes to ch2os register .......................................................... 16 change to the period measurement section ............................... 18 change to temperature measurement section ........................... 21 changes to figure 69 ...................................................................... 31 changes to figure 71 ...................................................................... 33 changes to the apparent energy section .................................... 36 changes to energies scaling section ............................................ 37 changes to calibration section ..................................................... 37 8/03revision 0: initial version
ade7753 rev. c | page 4 of 60 specifications av dd = dv dd = 5 v 5%, agnd = dgnd = 0 v, on-chip reference, clkin = 3.579545 mhz xtal, t min to t max = ?40c to +85c. see the plots in the typical performance characteristics section. table 1. parameter spec unit test conditions/comments energy measurement accuracy active power measurement error clkin = 3.579545 mhz channel 1 range = 0.5 v full scale channel 2 = 300 mv rms/60 hz, gain = 2 gain = 1 0.1 % typ over a dynamic range 1000 to 1 gain = 2 0.1 % typ over a dynamic range 1000 to 1 gain = 4 0.1 % typ over a dynamic range 1000 to 1 gain = 8 0.1 % typ over a dynamic range 1000 to 1 channel 1 range = 0.25 v full scale gain = 1 0.1 % typ over a dynamic range 1000 to 1 gain = 2 0.1 % typ over a dynamic range 1000 to 1 gain = 4 0.1 % typ over a dynamic range 1000 to 1 gain = 8 0.2 % typ over a dynamic range 1000 to 1 channel 1 range = 0.125 v full scale gain = 1 0.1 % typ over a dynamic range 1000 to 1 gain = 2 0.1 % typ over a dynamic range 1000 to 1 gain = 4 0.2 % typ over a dynamic range 1000 to 1 gain = 8 0.2 % typ over a dynamic range 1000 to 1 active power measurement bandwidth 14 khz phase error 1 between channels 1 0.05 max line frequency = 45 hz to 65 hz, hpf on ac power supply rejection 1 av dd = dv dd = 5 v + 175 mv rms/120 hz output frequency variation (cf) 0.2 % typ channel 1 = 20 mv rms, gain = 16, range = 0.5 v channel 2 = 300 mv rms/60 hz, gain = 1 dc power supply rejection 1 av dd = dv dd = 5 v 250 mv dc output frequency variation (cf) 0.3 % typ channel 1 = 20 mv rms/60 hz, gain = 16, range = 0.5 v channel 2 = 300 mv rms/60 hz, gain = 1 irms measurement error 0.5 % typ over a dynamic range 100 to 1 irms measurement bandwidth 14 khz vrms measurement error 0.5 % typ over a dynamic range 20 to 1 vrms measurement bandwidth 140 hz analog inputs 2 see the analog inputs section maximum signal levels 0.5 v max v1p, v1n, v2n, and v2p to agnd input impedance (dc) 390 k min bandwidth 14 khz clkin/256, clkin = 3.579545 mhz gain error 1 , 2 external 2.5 v reference, gain = 1 on channels 1 and 2 channel 1 range = 0.5 v full scale 4 % typ v1 = 0.5 v dc range = 0.25 v full scale 4 % typ v1 = 0.25 v dc range = 0.125 v full scale 4 % typ v1 = 0.125 v dc channel 2 4 % typ v2 = 0.5 v dc offset error 1 32 mv max gain 1 channel 1 13 mv max gain 16 32 mv max gain 1 channel 2 13 mv max gain 16 waveform sampling sampling clkin/128, 3.579545 mhz/128 = 27.9 ksps channel 1 see the channel 1 sampling section signal-to-noise plus distortion 62 db typ 150 mv rms/60 hz, range = 0.5 v, gain = 2 bandwidth(C3 db) 14 khz clkin = 3.579545 mhz
ade7753 rev. c | page 5 of 60 parameter spec unit test conditions/comments channel 2 see the channel 2 sampling section signal-to-noise plus distortion 60 db typ 150 mv rms/60 hz, gain = 2 bandwidth (C3 db) 140 hz clkin = 3.579545 mhz reference input ref in/out input voltage range 2.6 v max 2.4 v + 8% 2.2 v min 2.4 v C 8% input capacitance 10 pf max on-chip reference nominal 2.4 v at ref in/out pin reference error 200 mv max current source 10 a max output impedance 3.4 k min temperature coefficient 30 ppm/c typ clkin all specifications clkin of 3.579545 mhz input clock frequency 4 mhz max 1 mhz min logic inputs reset , din, sclk, clkin, and cs input high voltage, v inh 2.4 v min dv dd = 5 v 10% input low voltage, v inl 0.8 v max dv dd = 5 v 10% input current, i in 3 a max typically 10 na, v in = 0 v to dv dd input capacitance, c in 10 pf max logic outputs sag and irq open-drain outputs, 10 k pull-up resistor output high voltage, v oh 4 v min i source = 5 ma output low voltage, v ol 0.4 v max i sink = 0.8 ma zx and dout output high voltage, v oh 4 v min i source = 5 ma output low voltage, v ol 0.4 v max i sink = 0.8 ma cf output high voltage, v oh 4 v min i source = 5 ma output low voltage, v ol 1 v max i sink = 7 ma power supply for specified performance avdd 4.75 v min 5 v C 5% 5.25 v max 5 v + 5% dvdd 4.75 v min 5 v C 5% 5.25 v max 5 v + 5% ai dd 3 ma max typically 2.0 ma di dd 4 ma max typically 3.0 ma 1 see the terminology section for explanation of specifications. 2 see the analog inputs section. +2.1v 1.6ma i oh i ol 200 a c l 50pf 02875-0-002 to output pin figure 2. load circuit for timing specifications
ade7753 rev. c | page 6 of 60 timing characteristics av dd = dv dd = 5 v 5%, agnd = dgnd = 0 v, on-chip reference, clkin = 3.579545 mhz xtal, t min to t max = ?40c to +85c. sample tested during initial release and after any redesign or process change that could affect this parameter. all input signa ls are specified with tr = tf = 5 ns (10% to 90%) and timed from a voltage level of 1.6 v. see figure 3 , figure 4 , and the ade7753 serial interface section. table 2. parameter spec unit test conditions/comments write timing t 1 50 ns (min) cs falling edge to first sclk falling edge. t 2 50 ns (min) sclk logic high pulse width. t 3 50 ns (min) sclk logic low pulse width. t 4 10 ns (min) valid data setup time before falling edge of sclk. t 5 5 ns (min) data hold time after sclk falling edge. t 6 4 s (min) minimum time between the end of data byte transfers. t 7 50 ns (min) minimum time between byte transfers during a serial write. t 8 100 ns (min) cs hold time after sclk falling edge. read timing t 9 1 4 s (min) minimum time between read command (i.e., a write to communication register) and data read. t 10 50 ns (min) minimum time between data byte transfers during a multibyte read. t 11 30 ns (min) data access time after sclk rising edge following a write to the communications register. t 12 2 100 ns (max) bus relinquish time after falling edge of sclk. 10 ns (min) t 13 3 100 ns (max) bus relinquish time after rising edge of cs . 10 ns (min) 1 minimum time between read command and data read for all registers except waveform register, which is t 9 = 500 ns min. 2 measured with the load circuit in figure 2 and defined as the time required for the output to cross 0.8 v or 2.4 v. 3 derived from the measured time taken by the data outputs to change 0.5 v when loaded with the circ uit in figure 2. the measure d number is then extrapolated back to remove the effects of charging or discharging the 50 pf capacitor. this means that the time quoted in the timing characteris tics is the true bus relinquish time of the part and is independent of the bus loading. din scl k cs t 2 t 3 t 1 t 4 t 5 t 7 t 6 t 8 command byte most significant byte least significant byte 1 0 a4a5 a3 a2 a1 a0 db7 db0 db7 db0 t 7 02875-0-081 figure 3. serial write timing sclk cs t 1 t 10 t 13 0 0 a4a5 a3 a2 a1 a0 db0 db7 db0 db7 din dout t 11 t 11 t 12 command byte most significant byte least significant byte t 9 02875-0-083 figure 4. serial read timing
ade7753 rev. c | page 7 of 60 absolute maximum ratings t a = 25c, unless otherwise noted. table 3. parameter rating avdd to agnd C0.3 v to +7 v dvdd to dgnd C0.3 v to +7 v dvdd to avdd C0.3 v to +0.3 v analog input voltage to agnd, v1p, v1n, v2p, and v2n C6 v to +6 v reference input voltage to agnd C0.3 v to avdd + 0.3 v digital input voltage to dgnd C0.3 v to dvdd + 0.3 v digital output voltage to dgnd C0.3 v to dvdd + 0.3 v operating temperature range industrial C40c to +85c storage temperature range C65c to +150c junction temperature 150c 20-lead ssop, power dissipation 450 mw ja thermal impedance 112c/w lead temperature, soldering vapor phase (60 sec) 215c infrared (15 sec) 220c stresses above those listed under absolute maximum ratings may cause permanent damage to the device. this is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. exposure to absolute maximum rating conditions for extended periods may affect device reliability. esd caution esd (electrostatic discharge) sensitive device. electros tatic charges as high as 4000 v readily accumulate on the human body and test equipment and can discharge wi thout detection. although this product features proprietary esd protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. therefore, proper esd precautions are recommended to avoid performance degradation or loss of functionality.
ade7753 rev. c | page 8 of 60 terminology measurement error the error associated with the energy measurement made by the ade7753 is defined by the following formula: %100 7753 ? ? ? ? ? ? ? ? ? = energytrue energytrue ade register energy erro r percentage phase error between channels the digital integrator and the high-pass filter (hpf) in channel 1 have a non-ideal phase response. to offset this phase response and equalize the phase response between channels, two phase- correction networks are placed in channel 1: one for the digital integrator and the other for the hpf. the phase correction networks correct the phase response of the corresponding component and ensure a phase match between channel 1 (current) and channel 2 (voltage) to within 0.1 over a range of 45 hz to 65 hz with the digital integrator off. with the digital integrator on, the phase is corrected to within 0.4 over a range of 45 hz to 65 hz. power supply rejection this quantifies the ade7753 measurement error as a percentage of reading when the power supplies are varied. for the ac psr measurement, a reading at nominal supplies (5 v) is taken. a second reading is obtained with the same input signal levels when an ac (175 mv rms/120 hz) signal is introduced onto the supplies. any error introduced by this ac signal is expressed as a percentage of readingsee the measurement error definition. for the dc psr measurement, a reading at nominal supplies (5 v) is taken. a second reading is obtained with the same input signal levels when the supplies are varied 5%. any error introduced is again expressed as a percentage of the reading. adc offset error the dc offset associated with the analog inputs to the adcs. it means that with the analog inputs connected to agnd, the adcs still see a dc analog input signal. the magnitude of the offset depends on the gain and input range selectionsee the typical performance characteristics section. however, when hpf1 is switched on, the offset is removed from channel 1 (current) and the power calculation is not affected by this offset. the offsets can be removed by performing an offset calibrationsee the analog inputs section. gain error the difference between the measured adc output code (minus the offset) and the ideal output codesee the channel 1 adc and channel 2 adc sections. it is measured for each of the input ranges on channel 1 (0.5 v, 0.25 v, and 0.125 v). the difference is expressed as a percentage of the ideal code.
ade7753 rev. c | page 9 of 60 pin configuration and fu nction descriptions v2n 6 v2p 7 agnd 8 ref in/out 9 dgnd 10 clkin irq sag zx cf 15 14 13 12 11 ade7753 top view (not to scale) dvdd 2 avdd 3 v1p 4 v1n 5 dout sclk cs clkou t 19 18 reset 1 din 20 17 16 02875-0-005 figure 5. pin configuration (ssop package) table 4. pin function descriptions pin no. mnemonic description 1 reset 1 reset pin for the ade7753. a logic low on this pin holds the adcs and digital circuitry (including the serial in terface) in a reset condition. 2 dvdd digital power supply. this pin provides the supply vo ltage for the digital circuitry in the ade7753. the supply voltage should be maintained at 5 v 5% for specified operation. this pin should be decoupled to dgnd with a 10 f capacitor in parallel with a ceramic 100 nf capacitor. 3 avdd analog power supply. this pin provides the supply vo ltage for the analog circuitry in the ade7753. the supply should be maintained at 5 v 5% for specif ied operation. every effort should be made to minimize power supply ripple and noise at this pin by the use of proper decoupling. the typical performance graphs show the power supply rejection performance. this pin should be decoupled to agnd with a 10 f capacitor in parallel with a ceramic 100 nf capacitor. 4, 5 v1p, v1n analog inputs for channel 1. this channel is intended for use with a di/dt current transducer such as a rogowski coil or another current sensor such as a sh unt or current transformer (ct). these inputs are fully differential voltage inputs with maximum differential input signal levels of 0.5 v, 0.25 v, and 0.125 v, depending on the full-scale selectionsee the analog inputs section. channel 1 also has a pga with gain selections of 1, 2, 4, 8, or 16. the maximum signal leve l at these pins with respect to agnd is 0.5 v. both inputs have internal esd protection circuitry, and, in addition, an overvoltage of 6 v can be sustained on these inputs without risk of permanent damage. 6, 7 v2n, v2p analog inputs for channel 2. this channel is intended for use with the voltage transducer. these inputs are fully differential voltage inputs with a maximum differen tial signal level of 0.5 v. channel 2 also has a pga with gain selections of 1, 2, 4, 8, or 16. the maximu m signal level at these pins with respect to agnd is 0.5 v. both inputs have internal esd protection circuitry, and an overvoltage of 6 v can be sustained on these inputs without risk of permanent damage. 8 agnd analog ground reference. this pin provides the grou nd reference for the analog circuitry in the ade7753, i.e., adcs and reference. this pin should be tied to the analog ground plan e or the quietest ground reference in the system. this quiet ground reference should be used for all analog circuitry, for example, anti-aliasing filters, current and voltage transducers, etc. to keep ground noise around the ade7753 to a minimum, the quiet ground plane shou ld connected to the digital ground plane at only one point. it is acceptable to place the entire device on the analog ground plane. 9 ref in/out access to the on-chip voltage reference. the on-chip reference has a nominal value of 2.4 v 8% and a typical temperature coefficient of 30 ppm/c. an extern al reference source can also be connected at this pin. in either case, this pin should be deco upled to agnd with a 1 f ceramic capacitor. 10 dgnd digital ground reference. this pin provides the grou nd reference for the digital circuitry in the ade7753, i.e., multiplier, filters, and digital-to-frequency conv erter. because the digital return currents in the ade7753 are small, it is acceptable to connect this pin to th e analog ground plane of the system. however, high bus capacitance on the dout pin could result in noisy digital current, which could affect performance. 11 cf calibration frequency logic output. the cf logic outp ut gives active power information. this output is intended to be used for operational and calibrat ion purposes. the full-scale output frequency can be adjusted by writing to the cfden and cfnum registerssee the energy-to-frequency conversion section.
ade7753 rev. c | page 10 of 60 pin no. mnemonic description 12 zx voltage waveform (channel 2) zero-crossing output. this output toggles logic high and logic low at the zero crossing of the differential signal on channel 2see the zero-crossing detection section. 13 sag this open-drain logic output goes active low when either no zero crossings are detected or a low voltage threshold (channel 2) is crossed for a specified durationsee the line voltage sag detection section. 14 irq interrupt request output. this is an active low open-dr ain logic output. maskable interrupts include active energy register rollover, active energy register at ha lf level, and arrivals of new waveform samplessee the ade7753 interrupts section. 15 clkin master clock for adcs and digital signal processing. an external clock can be provided at this logic input. alternatively, a parallel resonant at crystal can be connected across clkin and clkout to provide a clock source for the ade7753. the clock frequency for specified operation is 3.579545 mhz. ceramic load capacitors of between 22 pf and 33 pf should be used wi th the gate oscillator circuit. refer to the crystal manufacturers data sheet for load capacitance requirements. 16 clkout a crystal can be connected across this pin and clkin as described for pin 15 to provide a clock source for the ade7753. the clkout pin can drive one cmos load wh en either an external clock is supplied at clkin or a crystal is being used. 17 cs chip select. part of the 4-wire spi serial interface. this active low logic input allows the ade7753 to share the serial bus with several other devicessee the ade7753 serial interface section. 18 sclk serial clock input for the synchronous serial interface. all serial data transfers are synchronized to this clocksee the ade7753 serial interface section. the sclk has a schmitt-trigger input for use with a clock source that has a slow edge transition time, for example, opto-isolator output. 19 dout data output for the serial interface. data is shifted out at this pin on the rising edge of sclk. this logic output is normally in a high impedance state unless it is driving data onto th e serial data bussee the ade7753 serial interface section. 20 din data input for the serial interface. data is shifted in at this pin on the falling edge of sclksee the ade7753 serial interface section. 1 it is recommended to dr ive the reset, sclk, and cs pins with either a push-pull without an external series resistor or with an open-collector with a 10 k pull-up resistor . pull-down resistors are not reco mmended because under some conditions, they may interact with internal circuitry.
ade7753 rev. c | page 11 of 60 typical performance characteristics full-scale current (%) error (%) 0.1 ?0.5 ?0.1 ?0.2 ?0.3 ?0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-006 +85c, pf = 0.5 +25c, pf = 0.5 gain = 1 integrator off internal reference +25c, pf = 1 ?40c, pf = 0.5 figure 6. active energy error as a percentage of reading (gain = 1) over power factor with internal reference and integrator off full-scale current (%) error (%) 0.1 ?0.4 ?0.2 ?0.1 ?0.3 0.1 0.4 0.3 0.2 0 1 10 100 02875-0-008 +25c, pf = 1 gain = 8 integrator off internal reference ?40c, pf = 1 +85c, pf = 1 figure 7. active energy as a percentage of reading (gain = 8) over temperature with internal reference and integrator off full-scale current (%) error (%) 0.1 ?0.6 ?0.2 ?0.4 0.2 0.8 0.6 0.4 0 1 10 100 02875-0-009 +85c, pf = 0.5 gain = 8 integrator off internal reference ?40c, pf = 0.5 +25c, pf = 1 +25c, pf = 0.5 figure 8. active energy error as a percentage of reading (gain = 8) over power factor with internal reference and integrator off full-scale current (%) error (%) 0.1 ?0.3 ?0.1 ?0.2 0.1 0.3 0.2 0 1 10 100 gain = 8 integrator off external reference +85c, pf = 1 02875-0-010 ?40c, pf = 1 +25c, pf = 1 figure 9. active energy error as a percentage of reading (gain = 8) over temperature with external reference and integrator off full-scale current (%) error (%) 0.1 ?0.6 ?0.2 ?0.4 0.2 0.6 0.4 0 1 10 100 gain = 8 integrator off external reference +85c, pf = 0.5 02875-0-011 ?40c, pf = 0.5 +25c, pf = 0.5 +25c, pf = 1 figure 10. active energy error as a percentage of reading (gain = 8) over power factor with external reference and integrator off full-scale current (%) error (%) 0.1 ?0.5 ?0.1 ?0.2 ?0.3 ?0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-012 +85c, pf = 0.5 +25c, pf = 0.5 gain = 1 integrator off internal reference +25c, pf = 0 ?40c, pf = 0.5 figure 11. reactive energy error as a percentage of reading (gain = 1) over power factor with internal reference and integrator off
ade7753 rev. c | page 12 of 60 full-scale current (%) error (%) 0.1 ?0.5 ?0.1 ?0.2 ?0.3 ?0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-013 +85c, pf = 0.5 +25c, pf = 0.5 gain = 1 integrator off external reference +25c, pf = 0 ?40c, pf = 0.5 figure 12. reactive energy error as a percentage of reading (gain = 1) over power factor with external reference and integrator off full-scale current (%) error (%) 0.1 ?0.20 ?0.10 ?0.05 ?0.15 0.05 0.20 0.15 0.10 0 1 10 100 02875-0-014 +85c, pf = 0 gain = 8 integrator off internal reference ?40c, pf = 0 +25c, pf = 0 figure 13. reactive energy error as a percentage of reading (gain = 8) over temperature with internal reference and integrator off full-scale current (%) error (%) 0.1 ?0.3 ?0.1 ?0.2 0.1 0.3 0.2 0 1 10 100 gain = 8 integrator off internal reference 02875-0-015 +25c, pf = 0.5 +25c, pf = 0 ?40c, pf = 0.5 +85c, pf = 0.5 figure 14. reactive energy error as a percentage of reading (gain = 8) over power factor with internal reference and integrator off full-scale current (%) error (%) 0.1 ?0.35 ?0.15 ?0.05 ?0.25 0.05 0.35 0.25 0.15 1 10 100 gain = 8 integrator off external reference 02875-0-016 ?40c, pf = 0 +85c, pf = 0 +25c, pf = 0 figure 15. reactive energy error as a percentage of reading (gain = 8) over temperature with external reference and integrator off full-scale current (%) error (%) 0.1 ?0.5 ?0.1 ?0.2 ?0.3 ?0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-017 gain = 8 integrator off external reference +25c, pf = 0 +85c, pf = 0.5 ?40c, pf = 0.5 +25c, pf = 0.5 figure 16. reactive energy error as a percentage of reading (gain = 8) over power factor with external reference and integrator off full-scale current (%) error (%) 0.1 ?0.3 ?0.1 ?0.2 0.1 0.3 0.2 0 1 10 100 gain = 8 integrator off internal reference 5.25v 02875-0-018 4.75v 5.0v figure 17. active energy error as a percentage of reading (gain = 8) over power supply with internal reference and integrator off
ade7753 rev. c | page 13 of 60 line frequency (hz) error (%) 45 ?0.1 ?0.2 ?0.4 ?0.6 ?0.8 0.4 0.2 0.1 0.8 0.6 0 50 55 60 6 5 02875-0-019 pf = 0.5 gain = 8 integrator off external reference pf = 1 figure 18. active energy error as a percentage of reading (gain = 8) over frequency with external reference and integrator off full-scale current (%) error (%) 0.1 ?0.5 ?0.1 ?0.2 ?0.3 ?0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-020 gain = 8 integrator off internal reference pf = 1 pf = 0.5 figure 19. irms error as a percentage of reading (gain = 8) with internal reference and integrator off full-scale current (%) error (%) 0.1 ?1.0 ?0.2 ?0.4 ?0.6 ?0.8 0.4 0.2 1.0 0.8 0.6 0 1 10 100 02875-0-022 gain = 8 integrator on internal reference +25c, pf = 0.5 ?40c, pf = 0.5 +85c, pf = 0.5 +25c, pf = 1 figure 20. active energy error as a percentage of reading (gain = 8) over power factor with internal reference and integrator on full-scale current (%) error (%) 0.1 ?1.0 ?0.2 ?0.4 ?0.6 ?0.8 0.4 0.2 1.0 0.8 0.6 0 1 10 100 02875-0-023 gain = 8 integrator on internal reference ?40c, pf = 1 85c, pf = 1 25c, pf = 1 figure 21. active energy error as a percentage of reading (gain = 8) over temperature with internal reference and integrator on full-scale current (%) error (%) 0.1 ?1.0 ?0.2 ?0.4 ?0.6 ?0.8 0.4 0.2 1.0 0.8 0.6 0 1 10 100 02875-0-024 gain = 8 integrator on internal reference +85c, pf = 0.5 ?40c, pf = 0.5 +25c, pf = 0.5 +25c, pf = 0 figure 22. reactive energy error as a percentage of reading (gain = 8) over power factor with internal reference and integrator on full-scale current (%) error (%) 0.1 ?1.0 ?0.2 ?0.4 ?0.6 ?0.8 0.4 0.2 1.0 0.8 0.6 0 1 10 100 02875-0-025 gain = 8 integrator on internal reference +85c, pf = 0 ?40c, pf = 0 +25c, pf = 0 figure 23. reactive energy error as a percentage of reading (gain = 8) over temperature with internal reference and integrator on
ade7753 rev. c | page 14 of 60 02875-0-026 ?2.0 ?1.5 ?1.0 ?0.5 0 0.5 1.0 1.5 2.0 2.5 3.0 error (%) 45 47 49 51 53 55 57 59 61 63 65 frequency (hz) gain = 8 integrator on internal reference pf = 0.5 pf = 1 figure 24. active energy error as a percentage of reading (gain = 8) over power factor with internal reference and integrator on full-scale current (%) error (%) 0.1 ?0.3 ?0.1 ?0.2 0.1 0.3 0.2 0 1 10 100 gain = 8 integrator on internal reference 5.25v 02875-0-027 4.75v 5.0v figure 25. active energy error as a percentage of reading (gain = 8) over power supply with internal reference and integrator on full-scale current (%) error (%) 0.1 ?0.5 ?0.1 ?0.2 ?0.3 ?0.4 0.2 0.1 0.5 0.4 0.3 0 1 10 100 02875-0-028 gain = 8 integrator on internal reference pf = 1 pf = 0.5 figure 26. irms error as a percentage of reading (gain = 8) with internal reference and integrator on full-scale voltage error (%) 1 ?0.2 ?0.4 ?0.6 ?0.8 0.4 0.2 0.8 0.6 0 10 100 02875-0-029 gain = 1 external reference figure 27. vrms error as a percentage of reading (gain = 1) with external reference 02875-0-087 ch1 offset (0p5v_1x) (mv) hits ?15 ?12 ?9 ?6 ?3 036 4 2 0 6 8 figure 28. channel 1 offset (gain = 1)
ade7753 rev. c | page 15 of 60 v dd 10 f 10 f 10 f 100nf 100nf avdd dvdd reset din dout sclk cs clkout clkin irq sag zx cf agnd dgnd v1p v1n v2n v2p ref in/out u1 ade7753 to spi bus (used only for calibration) 22pf 22pf y1 3.58mhz not connected u3 ps2501-1 i di/dt current sensor 100 1k 33nf 33nf 100 1k 33nf 33nf 1k 33nf 600k 110v 1k 33nf 100nf channel 1 gain = 8 channel 2 gain = 1 to frequency counter 02875-a-012 figure 29. test circuit for performance curves with integrator on ct turn ratio = 1800:1 channel 2 gain = 1 rb 10 1.21 gain 1 (ch1) 1 8 not connected v dd 10 f1 f 100nf 100nf din dout sclk cs clkout clkin irq sag zx cf agnd dgnd v1p v1n v2n v2p ref in/out u1 ade7753 to spi bus (used only for calibration) 22pf 22pf y1 3.58mhz u3 ps2501-1 i current transformer 1k 33nf 1k 33nf 1k 33nf 600k 0 rb 110v 1k 33nf 10 f 100nf to frequency counter 02875-0-030 avdd dvdd reset figure 30. test circuit for performance curves with integrator off
ade7753 rev. c | page 16 of 60 theory of operation analog inputs the ade7753 has two fully differential voltage input channels. the maximum differential input voltage for input pairs v1p/v1n and v2p/v2n is 0.5 v. in addition, the maximum signal level on analog inputs for v1p/v1n and v2p/ v2n is 0.5 v with respect to agnd. each analog input channel has a programmable gain amplifier (pga) with possible gain selections of 1, 2, 4, 8, and 16. the gain selections are made by writing to the gain registersee figure 32. bits 0 to 2 select the gain for the pga in channel 1, and the gain selection for the pga in channel 2 is made via bits 5 to 7. figure 31 shows how a gain selection for channel 1 is made using the gain register. v1p v1n v in k v in + gain[7:0] 76 5 4 3 2 1 0 00 0 0 0 0 0 0 7654 3210 0000 0000 gain (k) selection offset adjust (50mv) ch1os[7:0] bits 0 to 5: sign magnitude coded offset correction bit 6: not used bit 7: digital integrator (on = 1, off = 0; default off) 02875-0-031 figure 31. pga in channel 1 in addition to the pga, channel 1 also has a full-scale input range selection for the adc. the adc analog input range selection is also made using the gain registersee figure 32. as mentioned previously, the maximum differential input voltage is 0.5 v. however, by using bits 3 and 4 in the gain register, the maximum adc input voltage can be set to 0.5 v, 0.25 v, or 0.125 v. this is achieved by adjusting the adc referencesee the ade7753 reference circuit section. table 5 summarizes the maximum differential input signal level on channel 1 for the various adc range and gain selections. table 5. maximum input signal levels for channel 1 max signal adc input range selection channel 1 0.5 v 0.25 v 0.125 v 0.5 v gain = 1 ? ? 0.25 v gain = 2 gain = 1 ? 0.125 v gain = 4 gain = 2 gain = 1 0.0625 v gain = 8 gain = 4 gain = 2 0.0313 v gain = 16 gain = 8 gain = 4 0.0156 v ? gain = 16 gain = 8 0.00781 v ? ? gain = 16 gain register* channel 1 and channel 2 pga control 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 addr: 0x0f * register contents show power-on defaults pga 2 gain select 000 = 1 001 = 2 010 = 4 011 = 8 100 = 16 pga 1 gain select 000 = 1 001 = 2 010 = 4 011 = 8 100 = 16 channel 1 full-scale select 00 = 0.5v 01 = 0.25v 10 = 0.125v 02875-0-032 figure 32. ade7753 analog gain register it is also possible to adjust offset errors on channel 1 and channel 2 by writing to the offset correction registers, ch1os and ch2os, respectively. these registers allow channel offsets in the range 20 mv to 50 mv (depending on the gain setting) to be removed. channel 1 and 2 offset registers are sign magni- tude coded. a negative number is applied to the channel 1 offset register, ch1os, for a negative offset adjustment. note that the channel 2 offset register is inverted. a negative number is applied to ch2os for a positive offset adjustment. it is not necessary to perform an offset correction in an energy measure- ment application if hpf in channel 1 is switched on. figure 33 shows the effect of offsets on the real power calculation. as seen from figure 33, an offset on channel 1 and channel 2 contributes a dc component after multiplication. because this dc component is extracted by lpf2 to generate the active (real) power information, the offsets contribute an error to the active power calculation. this problem is easily avoided by enabling hpf in channel 1. by removing the offset from at least one channel, no error component is generated at dc by the multiplication. error terms at cos( t) are removed by lpf2 and by integration of the active power signal in the active energy register (aenergy[23:0]) see the energy calculation section.
ade7753 rev. c | page 17 of 60 dc component (including error term) is extracted by the lpf for real power calculation frequency (rad/s) i os v v os i v os i os v i 2 0 2 02875-0-033 figure 33. effect of channel offsets on the real power calculation the contents of the offset correction registers are 6-bit, sign and magnitude coded. the weight of the lsb depends on the gain setting, i.e., 1, 2, 4, 8, or 16. table 6 shows the correctable offset span for each of the gain settings and the lsb weight (mv) for the offset correction registers. the maximum value that can be written to the offset correction registers is 31dsee figure 34. figure 34 shows the relationship between the offset correction register contents and the offset (mv) on the analog inputs for a gain setting of 1. in order to perform an offset adjustment, the analog inputs should be first connected to agnd, and there should be no signal on either channel 1 or channel 2. a read from channel 1 or channel 2 using the waveform register indicates the offset in the channel. this offset can be canceled by writing an equal and opposite offset value to the channel 1 offset register, or an equal value to the channel 2 offset register. the offset correction can be confirmed by performing another read. note when adjusting the offset of channel 1, one should disable the digital integrator and the hpf. table 6. offset correction rangechannels 1 and 2 gain correctable span lsb size 1 50 mv 1.61 mv/lsb 2 37 mv 1.19 mv/lsb 4 30 mv 0.97 mv/lsb 8 26 mv 0.84 mv/lsb 16 24 mv 0.77 mv/lsb ch1os[5:0] sign + 5 bits +50mv offset adjust 0x3f 0x00 0x1f ?50mv 0mv sign + 5 bits 01,1111b 11,1111b 02875-0-034 figure 34. channel 1 offset correction range (gain = 1) the current and voltage rms offsets can be adjusted with the irmsos and vrmsos registerssee channel 1 rms offset compensation and channel 2 rms offset compensation sections. di/dt current sensor and digital integrator a di/dt sensor detects changes in magnetic field caused by ac current. figure 35 shows the principle of a di/dt current sensor. magnetic field created by current (directly proportional to current) + emf (electromotive force) ? induced by changes in magnetic flux density (di/dt) 02875-0-035 figure 35. principle of a di/dt current sensor the flux density of a magnetic field induced by a current is directly proportional to the magnitude of the current. the changes in the magnetic flux density passing through a conductor loop generate an electromotive force (emf) between the two ends of the loop. the emf is a voltage signal, which is proportional to the di/dt of the current. the voltage output from the di/dt current sensor is determined by the mutual inductance between the current-carrying conductor and the di/dt sensor. the current signal needs to be recovered from the di/dt signal before it can be used. an integrator is therefore necessary to restore the signal to its original form. the ade7753 has a built-in digital integrator to recover the current signal from the di/dt sensor. the digital integrator on channel 1 is switched off by default when the ade7753 is powered up. setting the msb of ch1os register turns on the integrator. figure 36 to figure 39 show the magnitude and phase response of the digital integrator. frequency (hz) 10 gain (db) 0 ?10 ?20 ?30 ?40 ?50 10 2 10 3 02875-0-036 figure 36. combined gain response of the digital integrator and phase compensator
ade7753 rev. c | page 18 of 60 frequency (hz) 10 2 10 3 02875-0-037 freq ?88.0 phase (degrees) ?88.5 ?89.0 ?89.5 ?90.0 ?90.5 figure 37. combined phase response of the digital integrator and phase compensator frequency (hz) ?1.0 ?6.0 40 70 45 gain (db) 50 55 60 65 ?1.5 ?2.0 ?2.5 ?3.5 ?4.5 ?5.5 ?3.0 ?4.0 ?5.0 02875-0-038 figure 38. combined gain response of the digital integrator and phase compensator (40 hz to 70 hz) ?89.75 ?89.80 ?89.85 ?89.90 ?89.95 ?90.00 frequency (hz) phase (degrees) 40 45 70 50 55 60 65 ?90.05 ?89.70 02875-0-039 figure 39. combined phase response of the digital integrator and phase compensator (40 hz to 70 hz) note that the integrator has a C20 db/dec attenuation and an approximately C90 phase shift. when combined with a di/dt sensor, the resulting magnitude and phase response should be a flat gain over the frequency band of interest. the di/dt sensor has a 20 db/dec gain associated with it. it also generates signifi- cant high frequency noise, therefore a more effective anti- aliasing filter is needed to avoid noise due to aliasingsee the antialias filter section. when the digital integrator is switched off, the ade7753 can be used directly with a conventional current sensor such as a current transformer (ct) or with a low resistance current shunt. zero-crossing detection the ade7753 has a zero-crossing detection circuit on channel 2. this zero crossing is used to produce an external zero-crossing signal (zx), and it is also used in the calibration modesee the calibrating an energy meter based on the ade7753 section. the zero-crossing signal is also used to initiate a temperature measurement on the ade7753see the temperature measurement section. figure 40 shows how the zero-crossing signal is generated from the output of lpf1. 1, 2, 1, 8, 16 adc 2 reference 1 lpf1 f ? 3db = 140hz ?63% to +63% fs pga2 {gain [7:5]} v2p v2n v 2 zero cross zx to multiplier 2.32 @ 60hz 1.0 0.93 zx v2 lpf1 02875-0-040 figure 40. zero-crossing detection on channel 2 the zx signal goes logic high on a positive-going zero crossing and logic low on a negative-going zero crossing on channel 2. the zero-crossing signal zx is generated from the output of lpf1. lpf1 has a single pole at 140 hz (at clkin = 3.579545 mhz). as a result, there is a phase lag between the analog input signal v2 and the output of lpf1. the phase response of this filter is shown in the channel 2 sampling section. the phase lag response of lpf1 results in a time delay of approximately 1.14 ms (@ 60 hz) between the zero crossing on the analog inputs of channel 2 and the rising or falling edge of zx. the zero-crossing detection also drives the zx flag in the interrupt status register. the zx flag is set to logic 0 on the rising and falling edge of the voltage waveform. it stays low until the status register is read with reset. an active low in the irq output also appears if the corresponding bit in the interrupt enable register is set to logic 1.
ade7753 rev. c | page 19 of 60 the flag in the interrupt status register as well as the irq output are reset to their default values when the interrupt status register with reset (rststatus) is read. zero-crossing timeout the zero-crossing detection also has an associated timeout register, zxtout. this unsigned, 12-bit register is decremented (1 lsb) every 128/clkin seconds. the register is reset to its user programmed full-scale value every time a zero crossing is detected on channel 2. the default power on value in this register is 0xfff. if the internal register decrements to 0 before a zero crossing is detected and the dissag bit in the mode register is logic 0, the sag pin goes active low. the absence of a zero crossing is also indicated on the irq pin if the zxto enable bit in the interrupt enable register is set to logic 1. irrespective of the enable bit setting, the zxto flag in the interrupt status register is always set when the internal zxtout register is decremented to 0see the section. ade7753 interrupts the zxout register can be written/read by the user and has an address of 1dhsee the ade7753 serial interface section. the resolution of the register is 128/clkin seconds per lsb. thus the maximum delay for an interrupt is 0.15 second (128/clkin 2 12 ). figure 41 shows the mechanism of the zero-crossing timeout detection when the line voltage stays at a fixed dc level for more than clkin/128 zxtout seconds. 12-bit internal register value zxtout channel 2 zxto detection bit 02875-0-041 figure 41. zero-crossing timeout detection period measurement the ade7753 also provides the period measurement of the line. the period register is an unsigned 16-bit register and is updated every period. the msb of this register is always zero. the resolution of this register is 2.2 s/lsb when clkin = 3.579545 mhz, which represents 0.013% when the line fre- quency is 60 hz. when the line frequency is 60 hz, the value of the period register is approximately clkin/4/32/60 hz 16 = 7457d. the length of the register enables the measurement of line frequencies as low as 13.9 hz. the period register is stable at 1 lsb when the line is established and the measurement does not change. a settling time of 1.8 seconds is associated with this filter before the measurement is stable. power supply monitor the ade7753 also contains an on-chip power supply monitor. the analog supply (av dd ) is continuously monitored by the ade7753. if the supply is less than 4 v 5%, then the ade7753 goes into an inactive state, that is, no energy is accumulated when the supply voltage is below 4 v. this is useful to ensure correct device operation at power-up and during power-down. the power supply monitor has built-in hysteresis and filtering, which give a high degree of immunity to false triggering due to noisy supplies. av dd 5v 4v 0v ade7753 power-on inactive state sag inactive active inactive time 02875-0-042 figure 42. on-chip power supply monitor as seen in figure 42 , the trigger level is nominally set at 4 v. the tolerance on this trigger level is about 5%. the sag pin can also be used as a power supply monitor input to the mcu. the sag pin goes logic low when the ade7753 is in its inactive state. the power supply and decoupling for the part should be such that the ripple at avdd does not exceed 5 v 5%, as specified for normal operation. line voltage sag detection in addition to the detection of the loss of the line voltage signal (zero crossing), the ade7753 can also be programmed to detect when the absolute value of the line voltage drops below a certain peak value for a number of line cycles. this condition is illustrated in figure 43 .
ade7753 rev. c | page 20 of 60 sagcyc [7:0] = 0x04 3 line cycles sag reset high when channel 2 exceeds saglvl [7:0] full scale s a glvl [7:0] sag channel 2 02875-0-043 figure 43. ade7753 sag detection figure 43 shows the line voltage falling below a threshold that is set in the sag level register (saglvl[7:0]) for three line cycles. the quantities 0 and 1 are not valid for the sagcyc register, and the contents represent one more than the desired number of full line cycles. for example, when the sag cycle (sagcyc[7:0]) contains 0x04, the sag pin goes active low at the end of the third line cycle for which the line voltage (channel 2 signal) falls below the threshold, if the dissag bit in the mode register is logic 0. as is the case when zero crossings are no longer detected, the sag event is also recorded by setting the sag flag in the interrupt status register. if the sag enable bit is set to logic 1, the irq logic output goes active lowsee the section. the ade7753 interrupts sag pin goes logic high again when the absolute value of the signal on channel 2 exceeds the sag level set in the sag level register. this is shown in when the figure 43 sag pin goes high again during the fifth line cycle from the time when the signal on channel 2 first dropped below the threshold level. sag level set the contents of the sag level register (1 byte) are compared to the absolute value of the most significant byte output from lpf1 after it is shifted left by one bit, thus, for example, the nominal maximum code from lpf1 with a full-scale signal on channel 2 is 0x2518see the channel 2 sampling section. shifting one bit left gives 0x4a30. therefore writing 0x4a to the sag level register puts the sag detection level at full scale. writing 0x00 or 0x01 puts the sag detection level at 0. the sag level register is compared to the most significant byte of a waveform sample after the shift left and detection is made when the contents of the sag level register are greater. peak detection the ade7753 can also be programmed to detect when the absolute value of the voltage or current channel exceeds a specified peak value. figure 44 illustrates the behavior of the peak detection for the voltage channel. both channel 1 and channel 2 are monitored at the same time. pkv reset low when rststatus register is read vpklvl[7:0] v 2 read rststatus register pkv interrupt flag (bit 8 of status register ) 02875-0-088 figure 44. ade7753 peak level detection figure 44 shows a line voltage exceeding a threshold that is set in the voltage peak register (vpklvl[7:0]). the voltage peak event is recorded by setting the pkv flag in the interrupt status register. if the pkv enable bit is set to logic 1 in the interrupt mask register, the irq logic output goes active low. similarly, the current peak event is recorded by setting the pki flag in the interrupt status registersee the section. ade7753 interrupts peak level set the contents of the vpklvl and ipklvl registers are respectively compared to the absolute value of channel 1 and channel 2 after they are multiplied by 2. thus, for example, the nominal maximum code from the channel 1 adc with a full- scale signal is 0x2851ecsee the channel 1 sampling section. multiplying by 2 gives 0x50a3d8. therefore, writing 0x50 to the ipklvl register, for example, puts the channel 1 peak detection level at full scale and sets the current peak detection to its least sensitive value. writing 0x00 puts the channel 1 detection level at 0. the detection is done by comparing the contents of the ipklvl register to the incoming channel 1 sample. the irq pin indicates that the peak level is exceeded if the pki or pkv bits are set in the interrupt enable register (irqen[15:0]) at address 0x0a. peak level record the ade7753 records the maximum absolute value reached by channel 1 and channel 2 in tw o different registersipeak and vpeak, respectively. vpeak and ipeak are 24-bit unsigned registers. these registers are updated each time the absolute value of the waveform sample from the corresponding channel is above the value stored in the vpeak or ipeak register. the contents of the vpeak register correspond to 2 the maximum absolute value observed on the channel 2 input. the contents of ipeak represent the maximum absolute value observed on the channel 1 input. reading the rstvpeak and rstipeak registers clears their respective contents after the read operation.
ade7753 rev. c | page 21 of 60 using the ade7753 interrupts with an mcu ade7753 interrupts figure 46 shows a timing diagram with a suggested implemen- tation of ade7753 interrupt management using an mcu. at time t 1 , the irq line goes active low indicating that one or more interrupt events have occurred in the ade7753. the irq logic output should be tied to a negative edge-triggered external interrupt on the mcu. on detection of the negative edge, the mcu should be configured to start executing its interrupt service routine (isr). on entering the isr, all interrupts should be disabled by using the global interrupt enable bit. at this point, the mcu external interrupt flag can be cleared to capture interrupt events that occur during the current isr. when the mcu interrupt flag is cleared, a read from the status register with reset is carried out. this causes the irq line to be reset logic high (t 2 )see the section. the status register contents are used to determine the source of the interrupt(s) and therefore the appropriate action to be taken. if a subsequent interrupt event occurs during the isr, that event is recorded by the mcu external interrupt flag being set again (t 3 ). on returning from the isr, the global interrupt mask is cleared (same instruction cycle), and the external interrupt flag causes the mcu to jump to its isr once a gain. this ensures that the mcu does not miss any external interrupts. interrupt timing ade7753 interrupts are managed through the interrupt status register (status[15:0]) and the interrupt enable register (irqen[15:0]). when an interrupt event occurs in the ade7753, the corresponding flag in the status register is set to logic 1 see the interrupt status register section. if the enable bit for this interrupt in the interrupt enable register is logic 1, then the irq logic output goes active low. the flag bits in the status register are set irrespective of the state of the enable bits. to determine the source of the interrupt, the system master (mcu) should perform a read from the status register with reset (rststatus[15:0]). this is achieved by carrying out a read from address 0x0c. the irq output goes logic high on completion of the interrupt status register read commandsee the section. when carrying out a read with reset, the ade7753 is designed to ensure that no interrupt events are missed. if an interrupt event occurs just as the status register is being read, the event is not lost and the interrupt timing irq logic output is guaranteed to go high for the duration of the interrupt status register data transfer before going logic low again to indicate the pending interrupt. see the next section for a more detailed description. irq global interrupt mask set isr return global interrupt mask reset clear mcu interrupt flag read status with reset (0x05) isr action (based on status contents) mcu interrupt flag set mcu program sequence 02875-0-044 t 1 t 2 t 3 jump to isr jump to isr figure 45. ade7753 interrupt management sclk din dout irq t 11 t 11 t 9 t 1 read status register command status register contents db7 db7db0 cs 000 0 0101 db0 02875-0-045 figure 46. ade7753 interrupt timing
ade7753 rev. c | page 22 of 60 interrupt timing the ade7753 serial interface section should be reviewed first before reviewing the interrupt timing. as previously described, when the irq output goes low, the mcu isr must read the interrupt status register to determine the source of the interrupt. when reading the status register contents, the irq output is set high on the last falling edge of sclk of the first byte transfer (read interrupt status register command). the irq output is held high until the last bit of the next 15-bit transfer is shifted out (interrupt status register contents)see . if an interrupt is pending at this time, the figure 45 irq output goes low again. if no interrupt is pending, the irq output stays high. temperature measurement the ade7753 also includes an on-chip temperature sensor. a temperature measurement can be made by setting bit 5 in the mode register. when bit 5 is set logic high in the mode register, the ade7753 initiates a temperature measurement on the next zero crossing. when the zero crossing on channel 2 is detected, the voltage output from the temperature sensing circuit is connected to adc1 (channel 1) for digitizing. the resulting code is processed and placed in the temperature register (temp[7:0]) approximately 26 s later (96/clkin seconds). if enabled in the interrupt enable register (bit 5), the irq output goes active low when the temperature conversion is finished. the contents of the temperature register are signed (twos complement) with a resolution of approximately 1.5 lsb/c. the temperature register produces a code of 0x00 when the ambient temperature is approximately ?25c. the temperature measurement is uncalibrated in the ade7753 and has an offset tolerance as high as 25c. ade7753 analog-to-digital conversion the analog-to-digital conversion in the ade7753 is carried out using two second-order - adcs. for simplicity, the block diagram in figure 47 shows a first-order - adc. the converter is made up of the - modulator and the digital low-pass filter. 24 digital low-pass filter r c analog low-pass filter + ? v ref 1-bit dac integrator mclk/4 latched comparator .....10100101..... + ? 02875-0-046 figure 47. first-order -? adc a - modulator converts the input signal into a continuous serial stream of 1s and 0s at a rate determined by the sampling clock. in the ade7753, the sampling clock is equal to clkin/4. the 1-bit dac in the feedback loop is driven by the serial data stream. the dac output is subtracted from the input signal. if the loop gain is high enough, the average value of the dac out- put (and therefore the bit stream) can approach that of the input signal level. for any given input value in a single sampling interval, the data from the 1-bit adc is virtually meaningless. only when a large number of samples are averaged is a meaningful result obtained. this averaging is carried out in the second part of the adc, the digital low-pass filter. by averaging a large number of bits from the modulator, the low-pass filter can produce 24-bit data-words that are proportional to the input signal level. the - converter uses two techniques to achieve high resolution from what is essentially a 1-bit conversion technique. the first is oversampling. oversampling means that the signal is sampled at a rate (frequency), which is many times higher than the bandwidth of interest. for example, the sampling rate in the ade7753 is clkin/4 (894 khz) and the band of interest is 40 hz to 2 khz. oversampling has the effect of spreading the quantization noise (noise due to sampling) over a wider bandwidth. with the noise spread more thinly over a wider bandwidth, the quantization noise in the band of interest is loweredsee figure 48 . however, oversampling alone is not efficient enough to improve the signal-to-noise ratio (snr) in the band of interest. for example, an oversampling ratio of 4 is required just to increase the snr by only 6 db (1 bit). to keep the oversampling ratio at a reasonable level, it is possible to shape the quantization noise so that the majority of the noise lies at the higher frequencies. in the - modulator, the noise is shaped by the integrator, which has a high-pass-type response for the quantization noise. the result is that most of the noise is at the higher frequencies where it can be removed by the digital low-pass filter. this noise shaping is shown in figure 48 . 447 0 894 2 noise s ignal digital filter antilalias filter (rc) sampling frequency high resolution output from digital lpf shaped noise 447 0 894 2 noise s ignal frequency (khz) frequency (khz) 02875-0-047 figure 48. noise reduction due to oversampling and noise shaping in the analog modulator
ade7753 rev. c | page 23 of 60 antialias filter ade7753 reference circuit figure 50 shows a simplified version of the reference output circuitry. the nominal reference voltage at the ref in/out pin is 2.42 v. this is the reference voltage used for the adcs in the ade7753. however, channel 1 has three input range selections that are selected by dividing down the reference value used for the adc in channel 1. the reference value used for channel 1 is divided down to ? and ? of the nominal value by using an internal resistor divider, as shown in figure 50 . figure 47 also shows an analog low-pass filter (rc) on the input to the modulator. this filter is present to prevent aliasing. aliasing is an artifact of all sampled systems. aliasing means that frequency components in the input signal to the adc, which are higher than half the sampling rate of the adc, appear in the sampled signal at a frequency below half the sampling rate. figure 49 illustrates the effect. frequency components (arrows shown in black) above half the sampling frequency (also know as the nyquist frequency, i.e., 447 khz) are imaged or folded back down below 447 khz. this happens with all adcs regardless of the architecture. in the example shown, only frequencies near the sampling frequency, i.e., 894 khz, move into the band of interest for metering, i.e., 40 hz to 2 khz. this allows the use of a very simple lpf (low-pass filter) to attenuate high frequency (near 900 khz) noise, and prevents distortion in the band of interest. for conventional current sensors, a simple rc filter (single-pole lpf) with a corner frequency of 10 khz produces an attenuation of approximately 40 db at 894 khzsee figure 49 . the 20 db per decade attenuation is usually sufficient to eliminate the effects of aliasing for conventional current sensors. however, for a di/dt sensor such as a rogowski coil, the sensor has a 20 db per decade gain. this neutralizes the C20 db per decade attenuation produced by one simple lpf. therefore, when using a di/dt sensor, care should be taken to offset the 20 db per decade gain. one simple approach is to cascade two rc filters to produce the C40 db per decade attenuation needed. 60 a ptat 2.5v 1.7k 12.5k 12.5k 12.5k 12.5k ref in/out 2.42v maximum load = 10 a output impedance 6k reference input to adc channel 1 (range select) 2.42v, 1.21v, 0.6v 02875-0-049 figure 50. ade7753 reference circuit output the ref in/out pin can be overdriven by an external source, for example, an external 2.5 v reference. note that the nominal reference value supplied to the adcs is now 2.5 v, not 2.42 v, which has the effect of increasing the nominal analog input signal range by 2.5/2.42 100% = 3% or from 0.5 v to 0.5165 v. sampling frequency image frequencies aliasing effects 0 2 447 894 frequency (khz) 02875-0-048 the voltage of the ade7753 reference drifts slightly with temperaturesee the ade7753 specifications for the temperature coefficient specification (in ppm/c). the value of the temperature drift varies from part to part. since the reference is used for the adcs in both channels 1 and 2, any x% drift in the reference results in 2% deviation of the meter accuracy. the reference drift resulting from temperature changes is usually very small and it is typically much smaller than the drift of other components on a meter. however, if guaranteed temperature performance is needed, one needs to use an external voltage reference. alternatively, the meter can be calibrated at multiple temperatures. real-time compensation can be achieved easily by using the on-chip temperature sensor. figure 49. adc and signal processing in channel 1 outline dimensions adc transfer function the following expression relates the output of the lpf in the - adc to the analog input signal level. both adcs in the ade7753 are designed to produce the same output code for the same input signal level. channel 1 adc 144,262 0492.3)( = (1) figure 51 shows the adc and signal processing chain for channel 1. in waveform sampling mode, the adc outputs a signed twos complement 24-bit data-word at a maximum of 27.9 ksps (clkin/128). with the specified full-scale analog input signal of 0.5 v (or 0.25 v or 0.125 vsee the analog inputs section) the adc produces an output code that is approximately between 0x2851ec (+2,642,412d) and 0xd7ae14 (C2,642,412d)see figure 51 . therefore with a full-scale signal on the input of 0.5 v and an internal reference of 2.42 v, the adc output code is nominally 165,151 or 2851fh. the maximum code from the adc is 262,144; this is equivalent to an input signal level of 0.794 v. however, for specified performance, it is recommended that the full-scale input signal level of 0.5 v not be exceeded.
ade7753 rev. c | page 24 of 60 ? 1, ? 2, ? 4, ? 8, ? 16 analog input range digital integrator* dt hpf adc 1 reference 2.42v, 1.21v, 0.6 v v1 0v 0.5v, 0.25v, 0.125v, 62.5mv, 31.3mv, 15.6mv, channel 1 (current waveform) data range active and reactive power calculation waveform sample register current rms (irms) calculation 50hz v1p v1n pga1 v1 {gain[4:3]} {gain[2:0]} *when digital integrator is enabled, full-scale output data is attenuated depending on the signal frequency because the integrator has a ?20db/decade frequency response. when disabled, the output will not be further attenuated. adc output word range 0xd7ae14 0x00000 0x2851ec 0xd7ae14 0x000000 0x2851ec channel 1 (current waveform) data range after integrator (50hz) 0xei08c4 0x000000 0x1ef73c 60hz channel 1 (current waveform) data range after integrator (60hz) 0xe631f8 0x000000 0x19ce08 02875-0-052 figure 51. adc and signal processing in channel 1 channel 1 sampling the waveform samples can also be routed to the waveform register (mode[14:13] = 1,0) to be read by the system master (mcu). in waveform sampling mode, the wsmp bit (bit 3) in the interrupt enable register must also be set to logic 1. the active, apparent power, and energy calculation remain uninterrupted during waveform sampling. when in waveform sampling mode, one of four output sample rates can be chosen by using bits 11 and 12 of the mode register (wavsel1,0). the output sample rate can be 27.9 ksps, 14 ksps, 7 ksps, or 3.5 kspssee the mode register (0x09) section. the interrupt request output, irq , signals a new sample availability by going active low. the timing is shown in . the 24-bit waveform samples are transferred from the ade7753 one byte (eight bits) at a time, with the most significant byte shifted out first. the 24-bit data-word is right justifiedsee the section. the interrupt request output figure 52 ade7753 serial interface irq stays low until the interrupt routine reads the reset status register see the section. ade7753 interrupts channel 1 data (24 bits) read from waveform sign 0 irq sclk din dout 0 0 01 hex 02875-0-050 figure 52. waveform sampling channel 1 channel 1 rms calculation root mean square (rms) value of a continuous signal v(t) is defined as vrms = = t rms dttv t v 0 2 )( 1 (2) for time sampling signals, rms calculation involves squaring the signal, taking the average and obtaining the square root: vrms = = = n i rms iv n v 1 2 )( 1 (3) the ade7753 simultaneously calculates the rms values for channel 1 and channel 2 in different registers. figure 53 shows the detail of the signal processing chain for the rms calculation on channel 1. the channel 1 rms value is processed from the samples used in the channel 1 waveform sampling mode. the channel 1 rms value is stored in an unsigned 24-bit register (irms). one lsb of the channel 1 rms register is equivalent to one lsb of a channel 1 waveform sample. the update rate of the channel 1 rms measurement is clkin/4.
ade7753 rev. c | page 25 of 60 i rms (t) lpf3 hpf1 channel 1 0x1c82b3 0x00 + irmsos[11:0] irms current signal (i(t)) 2 26 2 25 sgn 2 27 2 17 2 16 2 15 02875-0-0051 0x 2851ec 0x 00 0x d7ae14 24 24 figure 53. channel 1 rms signal processing with the specified full-scale analog input signal of 0.5 v, the adc produces an output code that is approximately 2,642,412dsee the channel 1 adc section. the equivalent rms value of a full-scale ac signal are 1,868,467d (0x1c82b3). the current rms measurement provided in the ade7753 is accurate to within 0.5% for signal input between full scale and full scale/100. table 7 shows the settling time for the irms measurement, which is the time it takes for the rms register to reflect the value at the input to the current channel. the conversion from the register value to amps must be done externally in the microprocessor using an amps/lsb constant. to minimize noise, synchronize the reading of the rms register with the zero crossing of the voltage input and take the average of a number of readings. table 7. 95% 100% integrator off 219 ms 895 ms integrator on 78.5 ms 1340 ms channel 1 rms offset compensation the ade7753 incorporates a channel 1 rms offset compensa- tion register (irmsos). this is a 12-bit signed register that can be used to remove offset in the channel 1 rms calculation. an offset could exist in the rms calculation due to input noises that are integrated in the dc component of v 2 (t). the offset calibration allows the content of the irms register to match the theoretical value even when the channel 1 input is low. one lsb of the channel 1 rms offset is equivalent to 32,768 lsb of the square of the channel 1 rms register. assuming that the maximum value from the channel 1 rms calculation is 1,868,467d with full-scale ac inputs, then 1 lsb of the channel 1 rms offset represents 0.46% of measurement error at C60 db down of full scale. irms = 32768 2 0 + (4) where irms 0 is the rms measurement without offset correction. to measure the offset of the rms measurement, two data points are needed from non-zero input values, for example, the base current, i b , and i max /100. the offset can be calculated from these measurements. channel 2 adc channel 2 sampling in channel 2 waveform sampling mode (mode[14:13] = 1,1 and wsmp = 1), the adc output code scaling for channel 2 is not the same as channel 1. the channel 2 waveform sample is a 16-bit word and sign extended to 24 bits. for normal operation, the differential voltage signal between v2p and v2n should not exceed 0.5 v. with maximum volt age input (0.5 v at pga gain of 1), the output from the adc swings between 0x2852 and 0xd7ae (10,322d). however, before being passed to the wave- form register, the adc output is passed through a single-pole, low-pass filter with a cutoff frequency of 140 hz. the plots in figure 54 show the magnitude and phase response of this filter. frequency (hz) 0 10 1 10 2 10 3 phase (degrees) ?20 ?10 ?40 ?50 ?60 ?30 ?70 ?80 ?90 0 ?18 gain (db) 60hz, ? 0.73db 50hz, ? 0.52db 60hz, ? 23.2 50hz, ? 19.7 ?8 ?10 ?14 ?12 ?16 ?2 ?4 ?6 02875-0-053 figure 54. magnitude and phase response of lpf1 the lpf1 has the effect of attenuating the signal. for example, if the line frequency is 60 hz, then the signal at the output of lpf1 is attenuated by about 8%. db hz hz fh 73.0919.0 140 60 1 1 )( 2 ?== ? ? ? ? ? ? ? ? + = (5) note lpf1 does not affect the active power calculation. the signal processing chain in channel 2 is illustrated in figure 55 .
ade7753 rev. c | page 26 of 60 v1 adc 2 0v analog input range 0.5v, 0.25, 0.125, 62.5mv, 31.25mv reference lpf1 active and reactive energy calculation vrms calculation and waveform sampling (peak/sag/zx) pga2 1, 2, 4, 8, 16 {gain [7:5]} v2p v2n v2 2.42v 0x2852 0x2581 0xdae8 0xd7ae 0x0000 lpf output word range 02875-0-054 figure 55. adc and signal processing in channel 2 vrms[23:0] lpf3 |x| lpf1 channel 2 0x17d338 0x00 + + vrmos[11:0] v oltage signal (v(t)) 2 9 sgn 2 8 2 2 2 1 2 0 02875-0-0055 0x2518 0x0 0xdae8 figure 56. channel 2 rms signal processing channel 2 has only one analog input range (0.5 v differential). like channel 1, channel 2 has a pga with gain selections of 1, 2, 4, 8, and 16. for energy measurement, the output of the adc is passed directly to the multiplier and is not filtered. an hpf is not required to remove any dc offset since it is only required to remove the offset from one channel to eliminate errors due to offsets in the power calculation. when in waveform sampling mode, one of four output sample rates can be chosen by using bits 11 and 12 of the mode register. the available output sample rates are 27.9 ksps, 14 ksps, 7 ksps, or 3.5 kspssee the mode register (0x09) section. the interrupt request output irq signals that a sample is available by going active low. the timing is the same as that for channel 1, as shown in . figure 52 channel 2 rms calculation figure 56 shows the details of the signal processing chain for the rms estimation on channel 2. this channel 2 rms estimation is done in the ade7753 using the mean absolute value calculation, as shown in figure 56 . the channel 2 rms value is processed from the samples used in the channel 2 waveform sampling mode. the rms value is slightly attenuated because of lpf1. channel 2 rms value is stored in the unsigned 24-bit vrms register. the update rate of the channel 2 rms measurement is clkin/4. with the specified full-scale ac analog input signal of 0.5 v, the output from the lpf1 swings between 0x2518 and 0xdae8 at 60 hzsee the channel 2 adc section. the equivalent rms value of this full-scale ac signal is approximately 1,561,400 (0x17d338) in the vrms register. the voltage rms measure- ment provided in the ade7753 is accurate to within 0.5% for signal input between full scale and full scale/20. table 8 shows the settling time for the vrms measurement, which is the time it takes for the rms register to reflect the value at the input to the voltage channel. the conversion from the register value to volts must be done externally in the microprocessor using a volts/lsb constant. since the low-pass filtering used for calculating the rms value is imperfect, there is some ripple noise from 2 term present in the rms measurement. to minimize the noise effect in the reading, synchronize the rms reading with the zero crossings of the voltage input. table 8. 95 100 220 ms 670 ms channel 2 rms offset compensation the ade7753 incorporates a channel 2 rms offset compensation register (vrmsos). this is a 12-bit signed register that can be used to remove offset in the channel 2 rms calculation. an offset could exist in the rms calculation due to input noises and dc offset in the input samples. the offset calibration allows the contents of the vrms register to be maintained at 0 when no voltage is applied. one lsb of the channel 2 rms offset is equivalent to one lsb of the rms register. assuming that the maximum value from the channel 2 rms calculation is 1,561,400d with full-scale ac inputs, then one lsb of the channel 2 rms offset represents 0.064% of measurement error at C60 db down of full scale. vrms = vrms 0 + vrmsos (6) where vrms 0 is the rms measurement without offset correction. the voltage rms offset compensation should be done by testing the rms results at two non-zero input levels. one measurement can be done close to full scale and the other at approximately full scale/10. the voltage offset compensation can be derived
ade7753 rev. c | page 27 of 60 from these measurements. if the voltage rms offset register does not have enough range, the ch2os register can also be used. phase compensation when the hpf is disabled, the phase error between channel 1 and channel 2 is 0 from dc to 3.5 khz. when hpf is enabled, channel 1 has the phase response illustrated in figure 58 and figure 59 . also shown in figure 60 is the magnitude response of the filter. as can be seen from the plots, the phase response is almost 0 from 45 hz to 1 khz. this is all that is required in typical energy measurement applications. however, despite being internally phase compensated, the ade7753 must work with transducers, which could have inherent phase errors. for example, a phase error of 0.1 to 0.3 is not uncommon for a current transformer (ct). these phase errors can vary from part to part, and they must be corrected in order to perform accurate power calculations. the errors associated with phase mismatch are particularly noticeable at low power factors. the ade7753 provides a means of digitally calibrating these small phase errors. the ade7753 allows a small time delay or time advance to be introduced into the signal processing chain to compensate for small phase errors. because the compensation is in time, this technique should be used only for small phase errors in the range of 0.1 to 0.5. correcting large phase errors using a time shift technique can introduce significant phase errors at higher harmonics. the phase calibration register (phcal[5:0]) is a twos comple- ment signed single-byte register that has values ranging from 0x21 (C31d) to 0x1f (31d). the register is centered at 0x0d, so that writing 0x0d to the register gives 0 delay. by changing the phcal register, the time delay in the channel 2 signal path can change from C102.12 s to +39.96 s (clkin = 3.579545 mhz). one lsb is equivalent to 2.22 s (clkin/8) time delay or advance. a line frequency of 60 hz gives a phase resolution of 0.048 at the fundamental (i.e., 360 2.22 s 60 hz). figure 57 illustrates how the phase compensation is used to remove a 0.1 phase lead in channel 1 due to the external transducer. to cancel the lead (0.1) in channel 1, a phase lead must also be introduced into channel 2. the resolution of the phase adjustment allows the introduction of a phase lead in increment of 0.048. the phase lead is achieved by introducing a time advance into channel 2. a time advance of 4.48 s is made by writing ?2 (0x0b) to the time delay block, thus reducing the amount of time delay by 4.48 s, or equiva- lently, a phase lead of approximately 0.1 at line frequency of 60 hz. 0x0b represents C2 because the register is centered with 0 at 0x0d. 110100 1 50 pga1 v 1p v1n v 1 adc 1 hpf 24 pga2 v2p v2n v 2 adc 2 delay block 2.24s/lsb 24 lpf2 v2 v1 60hz 0.1 v1 v2 channel 2 delay reduced by 4.48s (0.1lead at 60hz) 0bh in phcal [5.0] phcal [5:0] --100s to +34s 60hz 02875-0-056 figure 57. phase calibration frequency (hz) phase (degrees) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 ?0.1 10 2 10 3 10 4 02875-0-057 figure 58. combined phase response of the hpf and phase compensation (10 hz to 1 khz) frequency (hz) 0.20 40 phase (degrees) 0.18 0.16 0.14 0.12 0.10 0.08 0 0.02 0.04 0.06 45 50 55 60 65 70 02875-0-058 figure 59. combined phase response of the hpf and phase compensation (40 hz to 70 hz)
ade7753 rev. c | page 28 of 60 frequency (hz) 0.4 error (%) 54 56 58 60 62 64 66 0.3 0.2 0.1 0.0 ?0.1 ?0.2 ?0.3 ?0.4 02875-0-059 figure 60. combined gain response of the hpf and phase compensation active power calculation power is defined as the rate of energy flow from source to load. it is defined as the product of the voltage and current wave- forms. the resulting waveform is called the instantaneous power signal and is equal to the rate of energy flow at every instant of time. the unit of power is the watt or joules/sec. equation 9 gives an expression for the instantaneous power signal in an ac system. v ( t ) = )sin(2 tv ? (7) i ( t ) = )sin(2 ti ? (8) where: v is the rms voltage. i is the rms current. )()()( titvtp = )2cos( )( tvivitp ?= (9) the average power over an integral number of line cycles (n) is given by the expression in equation 10. p = = nt vidttp nt 0 )( 1 (10) where: t is the line cycle period. p is referred to as the active or real power. note that the active power is equal to the dc component of the instantaneous power signal p(t) in equation 8, i.e., vi. this is the relationship used to calculate active power in the ade7753. the instantaneous power signal p(t) is generated by multiplying the current and voltage signals. the dc component of the instantaneous power signal is then extracted by lpf2 (low-pass filter) to obtain the active power information. this process is illustrated in figure 61 . instantaneous power signal p(t) = v i-v i cos(2 t) active real power signal = v i 0x19999a vi 0xccccd 0x00000 current i(t) = 2 i sin( t) voltage v(t) = 2 v sin( t) 02875-0-060 figure 61. active power calculation since lpf2 does not have an ideal brick wall frequency responsesee figure 62 , the active power signal has some ripple due to the instantaneous power signal. this ripple is sinusoidal and has a frequency equal to twice the line frequency. because the ripple is sinusoidal in nature, it is removed when the active power signal is integrated to calculate energysee the energy calculation section. frequency (hz) ?24 1 db ?20 3 10 30 100 ?12 ?16 ?8 ?4 0 02875-0-061 figure 62. frequency response of lpf2
ade7753 rev. c | page 29 of 60 apos[15:0] wgain[11:0] wdiv[7:0] lpf2 current channel voltage channel output lpf2 time (nt) 4 clkin t active power signal + + aenergy [23:0] outputs from the lpf2 are accumulated (integrated) in the internal active energy register upper 24 bits are accessible through aenergy[23:0] register 23 0 48 0 waveform register values 02875-0-063 % figure 63. ade7753 active energy calculation figure 63 shows the signal processing chain for the active power calculation in the ade7753. as explained, the active power is calculated by low-pass filtering the instantaneous power signal. note that when reading the waveform samples from the output of lpf2, the gain of the active energy can be adjusted by using the multiplier and watt gain register (wgain[11:0]). the gain is adjusted by writing a twos complement 12-bit word to the watt gain register. equation 11 shows how the gain adjustment is related to the contents of the watt gain register: ? ? ? ? ? ? ? ? ? ? ? ? ? ? + = 12 2 1 wgain power active wgain output (11) for example, when 0x7ff is written to the watt gain register, the power output is scaled up by 50%. 0x7ff = 2047d, 2047/2 12 = 0.5. similarly, 0x800 = C2048d (signed twos complement) and power output is scaled by C50%. each lsb scales the power output by 0.0244%. figure 64 shows the maximum code (in hex) output range for the active power signal (lpf2). note that the output range changes depending on the contents of the watt gain register. the minimum output range is given when the watt gain register contents are equal to 0x800, and the maximum range is given by writing 0x7ff to the watt gain register. this can be used to calibrate the active power (or energy) calculation in the ade7753. 0x133333 0xccccd 0x66666 0xf9999a 0xf33333 0xeccccd 0x00000 active power output positive power negative power 0x000 0x7ff 0x800 {wgain[11:0]} active power calibration range 02875-0-062 figure 64. active power calculation output range energy calculation as stated earlier, power is defined as the rate of energy flow. this relationship can be expressed mathematically in equation 12. dt de p = (12) where: p is power. e is energy. conversely, energy is given as the integral of power. = pdte (13)
ade7753 rev. c | page 30 of 60 for waveform accumulatioin 1 24 24 lpf2 v i 0x19999 0x19999a 0x000000 instantaneous power signal ? p(t) for wavef0rm sampling 32 0xccccd current signal ? i(t) hpf voltage signal? v(t) multiplier + + apos [15:0] 2 6 sgn 2 5 2 -6 2 -7 2 -8 02875-0-064 wgain[11:0] figure 65. active power signal processing the ade7753 achieves the integration of the active power signal by continuously accumulating the active power signal in an internal nonreadable 49-bit energy register. the active energy register (aenergy[23:0]) represents the upper 24 bits of this internal register. this discrete time accumulation or summation is equivalent to integration in continuous time. equation 14 expresses the relationship. ? ? ? ? ? ? == = 1 0 )( )( n t tntplimdttpe (14) where: n is the discrete time sample number. t is the sample period. the discrete time sample period ( t ) for the accumulation register in the ade7753 is 1.1s (4/clkin). as well as calculating the energy, this integration removes any sinusoidal components that might be in the active power signal. figure 65 shows this discrete time integration or accumulation. the active power signal in the waveform register is continuously added to the internal active energy register. this addition is a signed addition; therefore negative energy is subtracted from the active energy contents. the exception to this is when poam is selected in the mode[15:0] register. in this case, only positive energy contributes to the active energy accumulationsee the positive-only accumulation mode section. the output of the multiplier is divided by wdiv. if the value in the wdiv register is equal to 0, then the internal active energy register is divided by 1. wdiv is an 8-bit unsigned register. after dividing by wdiv, the active energy is accumulated in a 49-bit internal energy accumulation register. the upper 24 bits of this register are accessible through a read to the active energy register (aenergy[23:0]). a read to the raenergy register returns the content of the aenergy register and the upper 24 bits of the internal register are cleared. as shown in figure 65, the active power signal is accumulated in an internal 49-bit signed register. the active power signal can be read from the waveform register by setting mode[14:13] = 0,0 and setting the wsmp bit (bit 3) in the interrupt enable register to 1. like the channel 1 and channel 2 waveform sampling modes, the waveform date is available at sample rates of 27.9 ksps, 14 ksps, 7 ksps, or 3.5 kspssee figure 52. figure 66 shows this energy accumulation for full-scale signals (sinusoidal) on the analog inputs. the three curves displayed illustrate the minimum period of time it takes the energy register to roll over when the active power gain register contents are 0x7ff, 0x000, and 0x800. the watt gain register is used to carry out power calibration in the ade7753. as shown, the fastest integration time occurs when the watt gain register is set to maximum full scale, i.e., 0x7ff. 0x00,0000 0x7f,ffff 0x3f,ffff 0x40,0000 0x80,0000 aenergy [23:0] 6.2 48 12.5 time (minutes) wgain = 0x7ff wgain = 0x000 wgain = 0x800 02875-0-065 figure 66. energy register rollov er time for full-scale power (minimum and maximum power gain) note that the energy register contents rolls over to full-scale negative (0x800000) and continues to increase in value when the power or energy flow is positivesee figure 66. conversely, if the power is negative, the energy register underflows to full- scale positive (0x7fffff) and continues to decrease in value. by using the interrupt enable register, the ade7753 can be configured to issue an interrupt ( irq ) when the active energy register is greater than half-full (positive or negative) or when an overflow or underflow occurs. integration time under steady load as mentioned in the last section, the discrete time sample period (t) for the accumulation register is 1.1 s (4/clkin). with full-scale sinusoidal signals on the analog inputs and the wgain register set to 0x000, the average word value from each lpf2 is 0xccccdsee figure 61. the maximum positive value that can be stored in the internal 49-bit register is 2 48 or
ade7753 rev. c | page 31 of 60 0xffff,ffff,ffff before it overflows. the integration time under these conditions with wdiv = 0 is calculated as follows: time = xccccd0 ffffffff, xffff,0 1.12 s = 375.8 s = 6.26 min(15) when wdiv is set to a value different from 0, the integration time varies, as shown in equation 16. wdiv timetime wdiv = = 0 (16) power offset calibration the ade7753 also incorporates an active power offset register (apos[15:0]). this is a signed twos complement 16-bit register that can be used to remove offsets in the active power calculation see figure 65 . an offset could exist in the power calculation due to crosstalk between channels on the pcb or in the ic itself. the offset calibration allows the contents of the active power register to be maintained at 0 when no power is being consumed. the 256 lsbs (apos = 0x0100) written to the active power offset register are equivalent to 1 lsb in the waveform sample register. assuming the average value, output from lpf2 is 0xccccd (838,861d) when inputs on channels 1 and 2 are both at full scale. at ?60 db down on channel 1 (1/1000 of the channel 1 full-scale input), the average word value output from lpf2 is 838.861 (838,861/1,000). one lsb in the lpf2 output has a measurement error of 1/838.861 100% = 0.119% of the average value. the active power offset register has a resolution equal to 1/256 lsb of the waveform register, therefore the power offset correction resolution is 0.00047%/lsb (0.119%/256) at C60 db. energy-to-freque ncy conversion ade7753 also provides energy-to-frequency conversion for calibration purposes. after initial calibration at manufacturing, the manufacturer or end customer often verify the energy meter calibration. one convenient way to verify the meter calibration is for the manufacturer to provide an output frequency, which is proportional to the energy or active power under steady load conditions. this output frequency can provide a simple, single- wire, optically isolated interface to external calibration equipment. figure 67 illustrates the energy-to-frequency conversion in the ade7753. cfnum[11:0] cf 11 0 cfden[11:0] 11 0 aenergy[48:0] 48 0 02875-0-066 % dfc figure 67. ade7753 energy-to-frequency conversion a digital-to-frequency converter (dfc) is used to generate the cf pulsed output. the dfc generates a pulse each time 1 lsb in the active energy register is accumulated. an output pulse is generated when (cfden + 1)/(cfnum + 1) number of pulses are generated at the dfc output. under steady load conditions, the output frequency is proportional to the active power. the maximum output frequency, with ac input signals at full scale and cfnum = 0x00 and cfden = 0x00, is approximately 23 khz. the ade7753 incorporates two registers, cfnum[11:0] and cfden[11:0], to set the cf frequency. these are unsigned 12-bit registers, which can be used to adjust the cf frequency to a wide range of values. these frequency-scaling registers are 12-bit registers, which can scale the output frequency by 1/2 12 to 1 with a step of 1/2 12 . if the value 0 is written to any of these registers, the value 1 would be applied to the register. the ratio (cfnum + 1)/ (cfden + 1) should be smaller than 1 to ensure proper operation. if the ratio of the registers (cfnum + 1)/(cfden + 1) is greater than 1, the register values would be adjusted to a ratio (cfnum + 1)/(cfden + 1) of 1. for example, if the output frequency is 1.562 khz while the contents of cfden are 0 (0x000), then the output frequency can be set to 6.1 hz by writing 0xff to the cfden register. when cfnum and cfden are both set to one, the cf pulse width is fixed at 16 clkin/4 clock cycles, approximately 18 s with a clkin of 3.579545 mhz. if the cf pulse output is longer than 180 ms for an active energy frequency of less than 5.56 hz, the pulse width is fixed at 90 ms. otherwise, the pulse width is 50% of the duty cycle. the output frequency has a slight ripple at a frequency equal to twice the line frequency. this is due to imperfect filtering of the instantaneous power signal to generate the active power signal see the active power calculation section. equation 9 from the active power calculation section gives an expression for the instantaneous power signal. this is filtered by lpf2, which has a magnitude response given by equation 17. 2 9.8 1 1 )( 2 f fh + = (17) the active power signal (output of lpf2) can be rewritten as p ( t ) = vi ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + 2 9.8 1 l 2f vi cos(4 f l t ) (18) where f l is the line frequency, for example, 60 hz. from equation 13, e ( t ) = vit ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + 2 9.8 14 l l 2f f vi sin(4 f l t ) (19)
ade7753 rev. c | page 32 of 60 from equation 19 it can be seen that there is a small ripple in the energy calculation due to a sin(2 t) component. this is shown graphically in figure 68 . the active energy calculation is shown by the dashed straight line and is equal to v i t. the sinusoidal ripple in the active energy calculation is also shown. since the average value of a sinusoid is 0, this ripple does not contribute to the energy calculation over time. however, the ripple can be observed in the frequency output, especially at higher output frequencies. the ripple gets larger as a percentage of the frequency at larger loads and higher output frequencies. the reason is simply that at higher output frequencies the integration or averaging time in the energy-to-frequency conversion process is shorter. as a consequence, some of the sinusoidal ripple is observable in the frequency output. choosing a lower output frequency at cf for calibration can significantly reduce the ripple. also, averaging the output frequency by using a longer gate time for the counter achieves the same results. vi ? sin(4 f l t) 4 f l (1+2 f l /8. 9hz ) e(t) t vlt 02875-0-067 figure 68. output frequency ripple wdiv[7:0] apos[15:0] wgain[11:0] lpf1 + + laenergy [23:0] accumulate active energy in internal register and update the laenergy register at the end of linecyc line cycles output from lpf2 from channel 2 adc 23 0 linecyc [15:0] 48 0 02875-0-068 % zero cross detection calibration control figure 69. energy calculation line cycle energy accumulation mode
ade7753 rev. c | page 33 of 60 line cycle energy accumulation mode in line cycle energy accumulation mode, the energy accumula- tion of the ade7753 can be synchronized to the channel 2 zero crossing so that active energy can be accumulated over an integral number of half line cycles. the advantage of summing the active energy over an integer number of line cycles is that the sinusoidal component in the active energy is reduced to 0. this eliminates any ripple in the energy calculation. energy is calculated more accurately and in a shorter time because the integration period can be shortened. by using the line cycle energy accumulation mode, the energy calibration can be greatly simplified, and the time required to calibrate the meter can be significantly reduced. the ade7753 is placed in line cycle energy accumulation mode by setting bit 7 (cycmode) in the mode register. in line cycle energy accumulation mode, the ade7753 accumulates the active power signal in the laenergy register (address 0x04) for an integral number of line cycles, as shown in figure 69 . the number of half line cycles is specified in the linecyc register (address 0x1c). the ade7753 can accumulate active power for up to 65,535 half line cycles. because the active power is integrated on an integral number of line cycles, at the end of a line cycle energy accumu- lation cycle the cycend flag in the interrupt status register is set (bit 2). if the cycend enable bit in the interrupt enable register is enabled, the irq output also goes active low. thus the irq line can also be used to sign al the completion of the line cycle energy accumulation. another calibration cycle can start as long as the cycmode bit in the mode register is set. from equations 13 and 18, e ( t ) = ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? + ? nt nt f vi dtvi 0 2 0 cos 9.8 1 (2 ft ) dt (20) where: n is an integer. t is the line cycle period. since the sinusoidal component is integrated over an integer number of line cycles, its value is always 0. therefore, e = + 0 (21) nt vidt 0 e ( t ) = vint (22) note that in this mode, the 16-bit linecyc register can hold a maximum value of 65,535. in other words, the line energy accumulation mode can be used to accumulate active energy for a maximum duration over 65,535 half line cycles. at 60 hz line frequency, it translates to a total duration of 65,535/120 hz = 546 seconds. positive-only accumulation mode in positive-only accumulation mode, the energy accumulation is done only for positive power, ignoring any occurrence of negative power above or below the no-load threshold, as shown in figure 70 . the cf pulse also reflects this accumulation method when in this mode. the ade7753 is placed in positive- only accumulation mode by setting the msb of the mode register (mode[15]). the default setting for this mode is off. transitions in the direction of power flow, going from negative to positive or positive to negative, set the irq pin to active low if the interrupt enable register is enabled. the interrupt status registers, ppos and pneg, show which transition has occurredsee the ade7753 register descriptions in . table 12 pneg ppos ppos interrupt status registers ppos pneg pneg irq no-load threshold active power no-load threshold a ctive energy 02875-0-069 figure 70. energy accumulation in positive-only accumulation mode no-load threshold the ade7753 includes a no-load threshold feature on the active energy that eliminates any creep effects in the meter. the ade7753 accomplishes this by not accumulating energy if the multiplier output is below the no-load threshold. this threshold is 0.001% of the full-scale output frequency of the multiplier. compare this value to the iec1036 specification, which states that the meter must start up with a load equal to or less than 0.4% ib. this standard translates to .0167% of the full-scale output frequency of the multiplier. reactive power calculation reactive power is defined as the product of the voltage and current waveforms when one of these signals is phase-shifted by
ade7753 rev. c | page 34 of 60 90. the resulting waveform is called the instantaneous reactive power signal. equation 25 gives an expression for the instanta- neous reactive power signal in an ac system when the phase of the current channel is shifted by +90. the average reactive power over an integral number of lines (n) is given in equation 26. v ( t ) = )sin(2 + tv (23) = = nt vidttrp nt rp 0 )sin( )( 1 (26) i ( t ) = )sin(2 ti ? ? ? ? ? ? + = 2 sin2)( titi (24) where: t is the line cycle period. rp is referred to as the reactive power. note that the reactive power is equal to the dc component of the instantaneous reactive power signal rp(t) in equation 25. this is the relationship used to calculate reactive power in the ade7753. the instantaneous reactive power signal rp(t) is generated by multiplying channel 1 and channel 2. in this case, the phase of channel 1 is shifted by +90. the dc component of the instantaneous reactive power signal is then extracted by a low-pass filter in order to obtain the reactive power informa- tion. figure 71 shows the signal processing in the reactive power calculation in the ade7753. where: is the phase difference between the voltage and current channel. v is the rms voltage. i is the rms current. rp ( t ) = v ( t ) i ( t ) (25) rp ( t ) = vi sin () + vi sin(2t + ) zero-crossing detection multiplier + + lvarenergy [23:0] accumulate reactive energy in internal register and update the lvarenergy register at the end of linecyc half line cycles instantaneous reactive power signal (rp(t)) 23 0 49 0 02875-0-070 lpf1 from channel 2 adc linecyc [15:0] lpf2 calibration control 2 v i 90 degree phase shift figure 71. reactive power signal processing
ade7753 rev. c | page 35 of 60 the features of the line reactive energy accumulation are the same as the line active energy accumulation. the number of half line cycles is specified in the linecyc register. linecyc is an unsigned 16-bit register. the ade7753 can accumulate reactive power for up to 65535 combined half cycles. at the end of an energy calibration cycle, the cycend flag in the interrupt status register is set. if the cycend mask bit in the interrupt mask register is enabled, the irq output also goes active low. thus the irq line can also be used to signal the end of a cali- bration. the ade7753 accumulates the reactive power signal in the lvarenergy register for an integer number of half cycles, as shown in . figure 71 sign of reactive power calculation note that the average reactive power is a signed calculation. the phase shift filter has C90 phase shift when the integrator is enabled, and +90 phase shift when the integrator is disabled. table 9 summarizes the relationship between the phase differ- ence between the voltage and the current and the sign of the resulting var calculation. table 9. sign of reactive power calculation angle integrator sign between 0 to 90 off positive between C90 to 0 off negative between 0 to 90 on positive between C90 to 0 on negative apparent power calculation the apparent power is defined as the maximum power that can be delivered to a load. v rms and i rms are the effective voltage and current delivered to the load; the apparent power (ap) is defined as v rms i rms . the angle between the active power and the apparent power generally represents the phase shift due to non- resistive loads. for single-phase applications, represents the angle between the voltage and the current signalssee figure 72 . reactive power apparent power active power 02875-0-071 figure 72. power triangle the apparent power is defined as v rms i rms . this expression is independent from the phase angle between the current and the voltage. figure 73 illustrates the signal processing in each phase for the calculation of the apparent power in the ade7753. v rms i rms 0xad055 apparent power signal (p) current rms signal ? i(t) voltage rms signal? v(t) multiplier 02875-0-072 0x00 0x1c82b3 0x00 0x17d338 vagain figure 73. apparent power signal processing the gain of the apparent energy can be adjusted by using the multiplier and vagain register (vagain[11:0]). the gain is adjusted by writing a twos complement, 12-bit word to the vagain register. equation 29 shows how the gain adjustment is related to the contents of the vagain register. ? ? ? ? ? ? ? ? ? ? ? ? ? ? + = 12 2 1 vagain power apparent in outputvaga (29) for example, when 0x7ff is written to the vagain register, the power output is scaled up by 50%. 0x7ff = 2047d, 2047/2 12 = 0.5. similarly, 0x800 = C2047d (signed twos complement) and power output is scaled by C50%. each lsb represents 0.0244% of the power output. the apparent power is calculated with the current and voltage rms values obtained in the rms blocks of the ade7753. figure 74 shows the maximum code (hexadecimal) output range of the apparent power signal. note that the output range changes depending on the contents of the apparent power gain registers. the minimum output range is given when the apparent power gain register content is equal to 0x800 and the maximum range is given by writing 0x7ff to the apparent power gain register. this can be used to calibrate the apparent power (or energy) calculation in the ade7753. 0x103880 0xad055 0x5682b 0x00000 0x000 0x7ff 0x800 {vagain[11:0]} apparent power 100% fs apparent power 150% fs apparent power 50% fs apparent power calibration range voltage and current channel inputs: 0.5v/gain 02875-0-073 figure 74. apparent power calculation output range apparent power o ffset calibration each rms measurement includes an offset compensation register to calibrate and eliminate the dc component in the rms valuesee channel 1 rms calculation and channel 2 rms calculation sections. the channel 1 and channel 2 rms values are then multiplied together in the apparent power signal processing. since no additional offsets are created in the multiplication of the rms values, there is no specific offset
ade7753 rev. c | page 36 of 60 compensation in the apparent power signal processing. the offset compensation of the apparent power measurement is done by calibrating each individual rms measurement. apparent energy calculation the apparent energy is given as the integral of the apparent power. = dttpower apparent energy apparent )( (30) the ade7753 achieves the integration of the apparent power signal by continuously accumulating the apparent power signal in an internal 49-bit register. the apparent energy register (vaenergy[23:0]) represents the upper 24 bits of this internal register. this discrete time accumulation or summation is equivalent to integration in continuous time. equation 31 expresses the relationship ? ? ? ? ? ? ? ? ? ? = = 0 0 )( n t tntpower apparent lim energy apparent (31) where: n is the discrete time sample number. t is the sample period. the discrete time sample period (t) for the accumulation register in the ade7753 is 1.1 s (4/clkin). figure 75 shows this discrete time integration or accumulation. the apparent power signal is continuously added to the internal register. this addition is a signed addition even if the apparent energy remains theoretically always positive. the 49 bits of the internal register are divided by vadiv. if the value in the vadiv register is 0, then the internal active energy register is divided by 1. vadiv is an 8-bit unsigned register. the upper 24 bits are then written in the 24-bit apparent energy register (vaenergy[23:0]). rvaenergy register (24 bits long) is provided to read the apparent energy. this register is reset to 0 after a read operation. figure 76 shows this apparent energy accumulation for full-scale signals (sinusoidal) on the analog inputs. the three curves displayed illustrate the minimum time it takes the energy register to roll over when the vagain registers content is equal to 0x7ff, 0x000, and 0x800. the vagain register is used to carry out an apparent power calibration in the ade7753. as shown, the fastest integration time occurs when the vagain register is set to maximum full scale, i.e., 0x7ff. vadiv apparent power + + vaenergy [23:0] apparent power are accumulated (integrated) in the apparent energy register 23 0 48 0 48 0 02875-0-074 % time (nt) t active power signal = p figure 75. ade7753 apparent energy calculation 0 xff,ffff 0x80,0000 0x40,0000 0x20,0000 0x00,0000 vaenergy[23:0] 6.26 12.52 18.78 25.04 time (minutes) vagain = 0x7ff vagain = 0x000 vagain = 0x800 02875-0-075 figure 76. energy register rollov er time for full-scale power (maximum and minimum power gain) note that the apparent energy register is unsignedsee figure 76 . by using the interrupt enable register, the ade7753 can be con- figured to issue an interrupt ( irq ) when the apparent energy register is more than half full or when an overflow occurs. the half full interrupt for the unsigned apparent energy register is based on 24 bits as opposed to 23 bits for the signed active energy register. integration times under steady load as mentioned in the last section, the discrete time sample period (t) for the accumulation register is 1.1 s (4/clkin). with full-scale sinusoidal signals on the analog inputs and the vagain register set to 0x000, the average word value from apparent power stage is 0xad055see the apparent power calculation section. the maximum value that can be stored in the apparent energy register before it overflows is 2 24 or 0xff,ffff. the average word value is added to the internal register, which can store 2 48 or 0xffff,ffff,ffff before it
ade7753 rev. c | page 37 of 60 overflows. therefore, the integration time under these conditions with vadiv = 0 is calculated as follows: line apparent energy accumulation time = 055xd0 ffffffff, xffff,0 1.2 s = 888 s = 12.52 min(32) when vadiv is set to a value different from 0, the integration time varies, as shown in equation 33. time = time wdiv = 0 vadiv (33) the ade7753 is designed with a special apparent energy accumulation mode, which simplifies the calibration process. by using the on-chip zero-crossing detection, the ade7753 accumulates the apparent power signal in the lvaenergy register for an integral number of half cycles, as shown in figure 77 . the line apparent energy accumulation mode is always active. the number of half line cycles is specified in the linecyc register, which is an unsigned 16-bit register. the ade7753 can accumulate apparent power for up to 65535 combined half cycles. because the apparent power is integrated on the same integral number of line cycles as the line active energy register, these two values can be compared easily. the active energy and the apparent energy are calculated more accurately because of this precise timing control and provide all the information needed for reactive power and power factor calculation. at the end of an energy calibration cycle, the cycend flag in the interrupt status register is set. if the cycend mask bit in the interrupt mask register is enabled, the irq output also goes active low. thus the irq line can also be used to signal the end of a calibration. the line apparent energy accumulation uses the same signal path as the apparent energy accumulation. the lsb size of these two registers is equivalent. vadiv[7:0] lpf1 + + lvaenergy [23:0] lvaenergy register is updated every linecyc zero crossings with the total apparent energy during that duration apparent power from channel 2 adc 23 0 linecyc [15:0] 48 0 02875-0-076 % zero-crossing detection calibration control figure 77. ade7753 apparent energy calibration
ade7753 rev. c | page 38 of 60 energies scaling the ade7753 provides measurements of active, reactive, and apparent energies. these measurements do not have the same scaling and thus cannot be compared directly to each other. table 10. energies scaling pf = 1 pf = 0.707 pf = 0 integrator on at 50 hz active wh wh 0.707 0 reactive 0 wh 0.508 wh 0.719 apparent wh 0.848 wh 0.848 wh 0.848 integrator off at 50 hz active wh wh 0.707 0 reactive 0 wh 0.245 wh 0.347 apparent wh 0.848 wh 0.848 wh 0.848 integrator on at 60 hz active wh wh 0.707 0 reactive 0 wh 0.610 wh 0.863 apparent wh 0.827 wh 0.827 wh 0.827 integrator off at 60 hz active wh wh 0.707 0 reactive 0 wh 0.204 wh 0.289 apparent wh 0.827 wh 0.827 wh 0.827 calibrating an energy meter based on the ade7753 the ade7753 provides gain and offset compensation for active and apparent energy calibration. its phase compensation corrects phase error in active, apparent and reactive energy. if a shunt is used, offset and phase calibration may not be required. a reference meter or an accurate source can be used to calibrate the ade7753. when using a reference meter, the ade7753 calibration output frequency, cf, is adjusted to match the frequency output of the reference meter. a pulse output is only provided for the active energy measurement in the ade7753. if it is desired to use a reference meter for calibrating the va and var, then additional code would have to be written in a microprocessor to produce a pulsed output for these quantities. otherwise, va and var calibration require an accurate source. the ade7753 provides a line cycle accumulation mode for calibration using an accurate source. in this method, the active energy accumulation rate is adjusted to produce a desired cf frequency. the benefit of using this mode is that the effect of the ripple noise in the active energy is eliminated. up to 65535 half line cycles can be accumulated, thus providing a stable energy value to average. the accumulation time is calculated from the line cycle period, measured by the ade7753 in the period register, and the number of half line cycles in the accumulation, fixed by the linecyc register. current and voltage rms offset calibration removes any apparent energy offset. a gain calibration is also provided for apparent energy. figure 79 shows an optimized calibration flow for active energy, rms, and apparent energy. active and apparent energy gain calibrations can take place concurrently, with a read of the accumulated apparent energy register following that of the accumulated active energy register. figure 78 shows the calibration flow for the active energy portion of the ade7753. watt gain calibration watt offset calibration phase calibration 02875-a-005 figure 78. active energy calibration the ade7753 does not provide means to calibrate reactive energy gain and offset. the reactive energy portion of the ade7753 can be calibrated externally, through a mcu. watt/va gain calibration watt offset calibration rms calibration phase calibration 02875-a-002 figure 79. apparent and ac tive energy calibration
ade7753 rev. c | page 39 of 60 watt gain the first step of calibrating the gain is to define the line voltage, base current and the maximum current for the meter. a meter constant needs to be determined for cf, such as 3200 imp/kwh or 3.2 imp/wh. note that the line voltage and the maximum current scale to half of their respective analog input ranges in this example. the expected cf in hz is cf expected (hz) = )cos( s/h3600 (w) (imp/wh) ? load ant meterconst (34) where ? is the angle between i and v, and cos is the power factor. )( ? the ratio of active energy lsbs per cf pulse is adjusted using the cfnum, cfden, and wdiv registers. cf expected = )1( )1 ( (s) + + cfden cfnum wdiv ontime accumulati laenergy (35) the relationship between watt-hours accumulated and the quantity read from aenergy can be determined from the amount of active energy accumulated over time with a given load: h laenerg y timeon accumulati load s/3600 (s) (w) lsb wh = (36) where accumulation time can be determined from the value in the line period and the number of half line cycles fixed in the linecyc register. accumulation time (s) = 2 (s) periodline linecyc ib (37) the line period can be determined from the period register: line period (s) = period clki n 8 (38) the aenergy wh/lsb ratio can also be expressed in terms of the meter constant: (imp/wh) )1( )1 ( lsb wh ant meterconst wdiv cfden cfnum + + = (39) in a meter design, wdiv, cfnum, and cfden should be kept constant across all meters to ensure that the wh/lsb constant is maintained. leaving wdiv at its default value of 0 ensures maximum resolution. the wdiv register is not included in the cf signal chain so it does not affect the frequency pulse output. the wgain register is used to finely calibrate each meter. cali- brating the wgain register changes both cf and aenergy for a given load condition. aenergy expected = aenergy nominal ? ? ? ? ? ? + 12 2 1 wgain (40) cf expected (hz) = cf nominal ? ? ? ? ? ? + + + 12 2 1 )1( )1 ( wgain cfden cfnum (41) when calibrating with a reference meter, wgain is adjusted until cf matches the reference meter pulse output. if an accurate source is used to calibrate, wgain is modified until the active energy accumulation rate yields the expected cf pulse rate. the steps of designing and calibrating the active energy portion of a meter with either a reference meter or an accurate source are outlined in the following examples. the specifications for this example are meter constant: meterconstant (imp/wh) = 3.2 base current: i b = 10 a maximum current: i max = 60 a line voltage: v nominal = 220 v line frequency: f l = 50 hz the first step in calibration with either a reference meter or an accurate source is to calculate the cf denominator, cfden. this is done by comparing the expected cf pulse output to the nominal cf output with the default cfden = 0x3f and cfnum = 0x3f and when the base current is applied. the expected cf output for this meter with the base current applied is 1.9556 hz using equation 34. cf ib ( expected ) (hz) = hz9556.1)cos( s/h3600 v220a10 imp/wh 200.3 =? alternatively, cf expected can be measured from a reference meter pulse output if available. cf expected (hz) = cf ref (42) the maximum cf frequency measured without any frequency division and with ac inputs at full scale is 23 khz. for this example, the nominal cf with the test current, i b , applied is 958 hz. in this example the line voltage and maximum current scale half of their respective analog input ranges. the line voltage and maximum current should not be fixed at the maximum analog inputs to account for occurrences such as spikes on the line. cf nominal (hz) = max i i 2 1 2 1 khz 23 (43) cf ib ( nominal ) (hz) = hz958 60 10 2 1 2 1 khz23 = the nominal cf on a sample set of meters should be measured using the default cfden, cfnum, and wdiv to ensure that the best cfden is chosen for the design. with the cfnum register set to 0, cfden is calculated to be 489 for the example meter:
ade7753 rev. c | page 40 of 60 cfden = 1 )( )( ? ? ? ? ? ? ? ? ? expectedib nominalib cf cf int (44) cfden = 489)1490(1 9556.1 958 =?=? ? ? ? ? ? ? int this value for cfden should be loaded into each meter before calibration. the wgain and wdiv registers can then be used to finely calibrate the cf output. the following sections explain how to calibrate a meter based on ade7753 when using a reference meter or an accurate source. calibrating watt gain using a reference meter example the cfden and cfnum values for the design should be written to their respective registers before beginning the calibration steps shown in figure 80 . when using a reference meter, the %error in cf is measured by comparing the cf output of the ade7753 meter with the pulse output of the reference meter with the same test conditions applied to both meters. equation 45 defines the percent error with respect to the pulse outputs of both meters (using the base current, i b ): % error cf ( ib ) = 100 )( )( ? ibref ibref ib cf cfcf (45) calculate cfden value for design write cfden value to cfden register addr. 0x15 = cfden write wgain value to the wgain register: addr. 0x12 measure the % error between the cf output and the reference meter output set i test = i b , v test = v nom , pf = 1 02875-a-006 calculate wgain. see equation 46. figure 80. calibrating watt gain using a reference meter for this example: meter constant: meterconstant (imp/wh) = 3.2 cf numerator: cfnum = 0 cf denominator: cfden = 489 % error measured at base current: % error cf ( ib ) = -3.07% one lsb change in wgain changes the active energy registers and cf by 0.0244%. wgain is a signed twos complement register and can correct for up to a 50% error. assuming a ?3.07% error, wgain is 126: wgain = int ? ? ? ? ? ? ? ? ? %0244.0 % )( ibcf error (46) wgain = int 126 %0244.0 %07.3 = ? ? ? ? ? ? ? ? when cf is calibrated, the aenergy register has the same wh/lsb constant from meter to meter if the meter constant, wdiv, and the cfnum/cfden ratio remain the same. the wh/lsb ratio for this meter is 6.378 10 ?4 using equation 39 with wdiv at the default value. (imp/wh) )1( )1 ( lsb wh ant meterconst wdiv cfden cfnum + + = 4 10378.6 2.3490 1 imp/wh 200.3 )1490( 1 lsb wh ? = = + = calibrating watt gain using an accurate source example the cfden value calculated using equation 44 should be written to the cfden register before beginning calibration and zero should be written to the cfnum register. first, the line accumulation mode and the line accumulation interrupt should be enabled. next, the number of half line cycles for the energy accumulation is written to the linecyc register. this sets the accumulation time. reset the interrupt status register and wait for the line cycle accumulation interrupt. the first line cycle accumulation results may not have used the accumulation time set by the linecyc register and should be discarded. after resetting the interrupt status register, the following line cycle readings will be valid. when li necyc half line cycles have elapsed, the irq pin goes active low and the nominal laenergy with the test current applied can be read. this laenergy value is compared to the expected laenergy value to deter- mine the wgain value. if apparent energy gain calibration is performed at the same time, lvaenergy can be read directly after laenergy. both registers should be read before the next interrupt is issued on the irq pin. refer to the section for more details. details the steps that calibrate the watt gain using an accurate source. apparent energy calculation figure 81
ade7753 rev. c | page 41 of 60 write wgain value to the wgain register: addr. 0x12 calculate cfden value for design write cfden value to cfden register addr. 0x15 = cfden set half linecycles for accumulation in linecyc register addr. 0x1c set i test = i b , v test = v nom , pf = 1 calculate wgain. see equation 47. set mode for line cycle accumulation addr. 0x09 = 0x0080 enable line cycle accumulation interrupt addr. 0x0a = 0x04 read line accumulation energy addr. 0x04 reset the interrupt status read register addr. 0x0c interrupt? no no yes yes 02875-a-007 reset the interrupt status read register addr. 0x0c interrupt? figure 81. calibrating watt gain using an accurate source equation 47 describes the relationship between the expected laenergy value and the laenergy measured in the test condition: wgain = int ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 12 )( )( 21 nominalib expectedib laenergy laenergy (47) the nominal laenergy reading, laenergy ib ( nominal ) , is the laenergy reading with the test current applied. the expected laenergy reading is calculated from the following equation: laenergy ib ( expected ) = int ? ? ? ? ? ? ? ? ? ? ? ? + + wdiv cfden cfnum timeon accumulati cf expectedib 1 1 (s) )( (48) where cf ib ( expected ) (hz) is calculated from equation 34, accumula- tion time is calculated from equation 37, and the line period is determined from the period register according to equation 38. for this example: meter constant: meterconstant (imp/wh) = 3.2 te s t cu r re nt : i b = 10 a line voltage: v nominal = 220 v line frequency: f l = 50 hz half line cycles: linecyc ib = 2000 cf numerator: cfnum = 0 cf denominator: cfden = 489 energy reading at base current: laenergy ib ( nominal ) = 17174 period register reading: period = 8959 clock frequency: clkin = 3.579545 mhz cf expected is calculated to be 1.9556 hz according to equation 34. laenergy expected is calculated to be 19186 using equation 48. cf ib ( expected ) (hz) = )(cos( s/h3600 a10v220 imp/wh 200.3 ? = 1.9556 hz laenergy ib ( expected ) = int ? ? ? ? ? ? ? ? ? ? ? ? + + wdiv cfden cfnum clkin period linecyc cf ib expectedib 1 1 /8 2/ )( laenergy ib ( expected ) = int 1 1489 1 )10579545.3/(889592/20009556.1 6 ? ? ? ? ? ? ? ? ? ? ? ? + = 19186)4.19186( = int wgain is calculated to be 480 using equation 47. wgain = int 48021 17174 19186 12 = ? ? ? ? ? ? ? ? ? ? ? ? ? note that wgain is a signed twos complement register. with wdiv and cfnum set to 0, laenergy can be expressed as
ade7753 rev. c | page 42 of 60 laenergy ib ( expected ) = ))1(/8 2/ ( )( + cfden clkin period linecyc cfint ib expectedib the calculated wh/lsb ratio for the active energy register, using equation 39 is 6.378 10 ?4 : 4 10378.6 imp/wh 200.3 )1489( 1 lsb wh ? = + = watt offset offset calibration allows outstanding performance over a wide dynamic range, for example, 1000:1. to do this calibration two measurements are needed at unity power factor, one at i b and the other at the lowest current to be corrected. either calibration frequency or line cycle accumulation measurements can be used to determine the energy offset. gain calibration should be performed prior to offset calibration. offset calibration is performed by determining the active energy error rate. once the active energy error rate has been determined, the value to write to the apos register to correct the offset is calculated. apos = ? clkin rateerror aenergy 35 2 (49) the aenergy registers update at a rate of clkin/4. the twos complement apos register provides a fine adjustment to the active power calculation. it represents a fixed amount of power offset to be adjusted every clkin/4. the 8 lsbs of the apos register are fractional such that one lsb of apos represents 1/256 of the least significant bit of the internal active energy register. therefore, one lsb of the apos register represents 2 ?33 of the aenergy[23:0] active energy register. the steps involved in determining the active energy error rate for both line accumulation and reference meter calibration options are shown in the following sections. calibrating watt offset usin g a reference meter example figure 82 shows the steps involved in calibrating watt offset with a reference meter. write apos value to the apos register: addr. 0x11 measure the % error between the cf output and the reference meter output, and the load in watts set i test = i min , v test = v nom , pf = 1 02875-a-008 calculate apos. see equation 49. figure 82. calibrating watt offset using a reference meter for this example: meter constant: meterconstant (imp/wh) = 3.2 minimum current: i min = 40 ma load at minimum current: w imin = 9.6 w cf error at minimum current: % error cf ( imin ) = 1.3% cf numerator: cfnum = 0 cf denominator: cfden = 489 clock frequency: clkin = 3.579545 mhz using equation 49, apos is calculated to be ?522 for this example. cf absolute error = cf imin ( nominal ) ? cf imin ( expected ) (50) cf absolute error = (% error cf ( imin ) ) w imin 3600 (imp/wh) ant meterconst (51) cf absolute error = hz 000110933.0 3600 200.3 6.9 100 %3.1 = ? ? ? ? ? ? then, aenergy error rate (lsb/s) = cf absolute error 1 1 + + cfnu m cfden (52) aenergy error rate (lsb/s) = 0.000110933 05436.0 1 490 = using equation 49, apos is ?522. apos = ? 522 10579545.3 205436.0 6 35 ?= apos can be represented as follows with cfnum and wdiv set at 0: apos = ? clki n cfden ant meterconst w error imin imincf 35 )( 2)1( 3600 (imp/wh) ) (% +
ade7753 rev. c | page 43 of 60 calibrating watt offset with an accurate source example figure 83 is the flowchart for watt offset calibration with an accurate source. set half line cycles for accumulation in linecyc register addr. 0x1c set i test = i min , v test = v nom , pf = 1 calculate apos. see equation 49. set mode for line cycle accumulation addr. 0x09 = 0x0080 enable line cycle accumulation interrupt addr. 0x0a = 0x04 read line accumulation energy addr. 0x04 reset the interrupt status read register addr. 0x0c interrupt? no no yes yes reset the interrupt status read register addr. 0x0c interrupt? write apos value to the apos register: addr. 0x11 02875-a-009 figure 83. calibrating watt offset with an accurate source for this example: meter constant: meterconstant (imp/wh) = 3.2 line voltage: v nominal = 220 v line frequency: f l = 50 hz cf numerator: cfnum = 0 cf denominator: cfden = 489 base current: i b = 10 a half line cycles used at base current: linecyc ( ib ) = 2000 period register reading: period = 8959 clock frequency: clkin = 3.579545 mhz expected laenergy register value at base current (from the watt gain section): laenergy ib ( expected ) = 19186 minimum current: i min = 40 ma number of half line cycles used at minimum current: linecyc ( imin) = 35700 active energy reading at minimum current: laenergy imin( nominal ) = 1395 the laenergy expected at i min is 1370 using equation 53. laenergy imin ( expected ) = int ? ? ? ? ? ? ? ? ib min expectedib b min linecyc linecyci laenergy i i )( (53) laenergy imin ( expected ) = int 1370)80.1369( 2000 35700 19186 10 04.0 = = ? ? ? ? ? ? int where: laenergy ib ( expected ) is the expected laenergy reading at i b from the watt gain calibration. linecyc imin is the number of half line cycles that energy is accumulated over when measuring at i min . more line cycles could be required at the minimum current to minimize the effect of quantization error on the offset calibration. for example, if a test current of 40 ma results in an active energy accumulation of 113 after 2000 half line cycles, one lsb variation in this reading represents an 0.8% error. this measurement does not provide enough resolution to calibrate out a <1% offset error. however, if the active energy is accumulated over 37,500 half line cycles, one lsb variation results in 0.05% error, reducing the quantization error. apos is ? 672 using equations 55 and 49. laenergy absolute error = laenergy imin ( nominal ) ? laenergy imin ( expected ) laenergy absolute error = 1395 ? 1370 = 25 (54) aenergy error rate (lsb/s) = period clkin linecy c error absolute laenergy 82/ (55) aenergy error rate (lsb/s) = 069948771.0 89598 10579545.3 2/35700 25 6 = apos = ? clki n rateerror aenergy 35 2 apos = ? 672 10579545.3 2 069948771.0 6 35 ?=
ade7753 rev. c | page 44 of 60 phase calibration the phcal register is provided to remove small phase errors. the ade7753 compensates for phase error by inserting a small time delay or advance on the voltage channel input. phase leads up to 1.84 and phase lags up to 0.72 at 50 hz can be corrected. the error is determined by measuring the active energy at i b and two power factors, pf = 1 and pf =0.5 inductive. some cts may introduce large phase errors that are beyond the range of the phase calibration register. in this case, coarse phase compensation has to be done externally with an analog filter. the phase error can be obtained from either cf or laenergy measurements: error = 2 2 )( )( 5., expectedib expectedib pfib laenergy laenergy laenergy ? = (56) if watt gain and offset calibration have been performed, there should be 0% error in cf at unity power factor and then: error = % error cf ( ib,pf = .5) /100 (57) the phase error is phase error () = ?arcsin ? ? ? ? ? ? ? ? 3 error (58) the relationship between phase error and the phcal phase correction register is phcal = int () + ? ? ? ? ? ? 360 period errorphase 0x0d (59) the expression for phcal can be simplified using the assumption that at small x: arcsin( x ) x the delay introduced in the voltage channel by phcal is delay = ( phcal ? 0x0d) 8/ clkin (60) the delay associated with the phcal register is a time delay if ( phcal ? 0x0d) is positive but represents a time advance if this quantity is negative. there is no time delay if phcal = 0x0d. the phase correction is in the opposite direction of the phase error. phase correction () = ?( phcal ? 0x0d) period 360 (61) calibrating phase using a reference meter example a power factor of 0.5 inductive can be assumed if the pulse output rate of the reference meter is half of its pf = 1 rate. then the %error between cf and the pulse output of the reference meter can be used to perform the preceding calculations. write phcal value to the phcal register: addr. 0x10 measure the % error between the cf output and the reference meter output set i test = i b , v test = v nom , pf = 0.5 02875-a-010 calculate phcal. see equation 59. figure 84. calibrating phase using a reference meter for this example: cf % error at pf = .5 inductive: % error cf ( ib,pf = .5 ) = 0.215% period register reading: period = 8959 then phcal is 11 using equations 57 through 59: error = 0.215% / 100 = 0.00215 phase error () = ?arcsin ?= ? ? ? ? ? ? ? ? 07.0 3 00215.0 phcal = int ? ? ? ? ? ? ? 360 8959 07.0 + 0x0d = ?2 + 13 = 11 phcal can be expressed as follows: phcal = int ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 2 3 arcsin period error + 0x0d (62) note that phcal is a signed twos complement register. setting the phcal register to 11 provides a phase correction of 0.08 to correct the phase lead: phase correction () = period phcal ?? 360 )0x0d ( phase correction () = = ?? 08.0 8960 360 )0x0d11(
ade7753 rev. c | page 45 of 60 calibrating phase with an accurate source example with an accurate source, line cycle accumulation is a good method of calibrating phase error. the value of laenergy must be obtained at two power factors, pf = 1 and pf = 0.5 inductive. set half line cycles for accumulation in linecyc register addr. 0x1c set i test = i b , v test = v nom , pf = 0.5 calculate phcal. see equation 59. set mode for line cycle accumulation addr. 0x09 = 0x0080 enable line cycle accumulation interrupt addr. 0x0a = 0x04 read line accumulation energy addr. 0x04 reset the interrupt status read register addr. 0x0c interrupt? no no yes yes reset the interrupt status read register addr. 0x0c interrupt? write phcal value to the phcal register: addr. 0x10 02875-a-011 figure 85. calibrating phase with an accurate source for this example: meter constant: meterconstant (imp/wh) = 3.2 line voltage: v nominal = 220 v line frequency: f l = 50 hz cf numerator: cfnum = 0 cf denominator: cfden = 489 base current: i b = 10 a half line cycles used at base current: linecyc ib = 2000 period register: period = 8959 expected line accumulation at unity power factor (from watt gain section: laenergy ib ( expected ) = 19186 active energy reading at pf = .5 inductive: laenergy ib, pf = .5 = 9613 the error using equation 56 is error = 0021.0 2 19186 2 19186 9613 = ? phase error () = ?arcsin ?= ? ? ? ? ? ? ? ? 07.0 3 0021.0 using equation 59, phcal is calculated to be 11. phcal = int 111320x0d 360 8959 07.0 =+?=+ ? ? ? ? ? ? ? note that phcal is a signed twos complement register. the phase lead is corrected by 0.08 when the phcal register is set to 11: phase correction () = period phcal ?? 360 )0x0d ( phase correction () = = ?? 08.0 8960 360 )0x0d11( vrms and irms calibration vrms and irms are calculated by squaring the input in a digital multiplier. )2cos( )sin(v2)sin(v2)( t vvt t tv 22 2 ??= = (63) the square of the rms value is extracted from v 2 ( t ) by a low-pass filter. the square root of the output of this low-pass filter gives the rms value. an offset correction is provided to cancel noise and offset contributions from the input. there is ripple noise from the 2 term because the low-pass filter does not completely attenuate the signal. this noise can be minimized by synchronizing the rms register readings with the zero crossing of the voltage signal. the irq output can be configured to indicate the zero crossing of the voltage signal. this flowchart demonstrates how vrms and irms readings are synchronized to the zero crossings of the voltage input. set interrupt enable for zero crossing addr. 0x0a = 0x0010 reset the interrupt status read register addr. 0x0c interrupt? no yes 02875-a-003 read vrms or irms addr. 0x17; 0x16 reset the interrupt status read register addr. 0x0c figure 86. synchronizing vrms and irms readings with zero crossings
ade7753 rev. c | page 46 of 60 apparent energy voltage rms compensation is done after the lpf3 filter (see figure 56 ). apparent energy gain calibration is provided for both meter-to- meter gain adjustment and for setting the vah/lsb constant. vrms = vrms0 + vrmsos (64) vaenergy = ? ? ? ? ? ? + 12 2 1 1 vagain vadiv vaenergy initial (68) where: vrms0 is the rms measurement without offset correction. vrms is linear from full-scale to full-scale/20. vadiv is similar to the cfden for the watt hour calibration. it should be the same across all meters and determines the vah/lsb constant. vagain is used to calibrate individual meters. to calibrate the offset, two vrms measurements are required, for example, at v nominal and v nominal /10. v nominal is set at half of the full-scale analog input range so the smallest linear vrms reading is at v nominal /10. vrmsos = 12 1 22 1 vv vrmsvvrmsv ? ? (65) apparent energy gain calibration should be performed before rms offset correction to make most efficient use of the current test points. apparent energy gain and watt gain compensation require testing at i b while rms and watt offset correction require a lower test current. apparent energy gain calibration can be done at the same time as the watt-hour gain calibration using line cycle accumulation. in this case, laenergy and lva e n e r g y , the line cycle accumulation apparent energy register, are both read following the line cycle accumulation interrupt. figure 87 shows a flowchart for calibrating active and apparent energy simultaneously. where vrms 1 and vrms 2 are rms register values without offset correction for input v 1 and v 2 , respectively. if the range of the 12-bit, twos complement vrmsos register is not enough, the voltage channel offset register, ch2os, can be used to correct the vrms offset. current rms compensation is performed before the square root: irms 2 = irms0 2 + 32768 irmsos (66) vagain = int ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 12 )( )( 21 nominalib expectedib lvaenergy lvaenergy (69) where irms0 is the rms measurement without offset correction. the current rms calculation is linear from full-scale to full- scale/100. lva e n e r g y ib ( expected ) = int ? ? ? ? ? ? ? ? ? ? ? ? (s) s/h3600 timeon accumulati constant lsb vah iv b nominal (70) to calibrate this offset, two irms measurements are required, for example, at i b and i max /50. i max is set at half of the full-scale analog input range so the smallest linear irms reading is at i max /50. irmsos = 2 1 2 2 2 1 2 2 2 2 2 1 ii irmsiirmsi ? ? 32768 1 (67) the accumulation time is determined from equation 37 and the line period can be determined from the period register accord- ing to equation 38. the vah represented by the vaenergy register is where irms 1 and irms 2 are rms register values without offset correction for input i 1 and i 2 , respectively. vah = vaenergy vah / lsb constant (71) the vah/lsb constant can be verified using this equation: lvaenerg y timeon accumulati va constant lsb vah 3600 (s) = (72)
ade7753 rev. c | page 47 of 60 calculate cfden value for design write cfden value to cfden register addr. 0x15 = cfden set half line cycles for accumulation in linecyc register addr. 0x1c set i test = i b , v test = v nom , pf = 1 calculate wgain. see equation 47. set mode for line cycle accumulation addr. 0x09 = 0x0080 enable line cycle accumulation interrupt addr. 0x0a = 0x04 read line accumulation energy active energy: addr. 0x04 apparaent energy: addr. 0x07 reset the interrupt status read register addr. = 0x0c interrupt? no no yes yes 02875-a-004 reset the interrupt status read register addr. = 0x0c interrupt? write wgain value to addr. 0x12 calculate vagain. see equation 69. write vgain value to addr. 0x1a figure 87. active/apparent gain calibration reactive energy reactive energy is only available in line accumulation mode in the ade7753. the accumulated reactive energy over linecyc number of half line cycles is stored in the lvarenergy register. in the ade7753, a low-pass filter at 2 hz on the current channel is implemented for the reactive power calculation. this provides the 90 degree phase shift needed to calculate the reactive power. this filter introduces 1/f attenuation in the reactive energy accumulated. compensation for this attenuation can be done externally in a microcontroller. the microcontroller can use the lvarenergy register in order to produce a pulse output similar to the cf pulse for reactive energy. to create a var pulse, an impulse/varh constant must be determined. the 1/f attenuation correction factor is determined by comparing the nominal reactive energy accumulation rate to the expected value. the attenuation correction factor is multi- plied by the contents of the lvarenergy register, with the ade7753 in line accumulation mode.
ade7753 rev. c | page 48 of 60 the impulse/lsb ratio used to convert the value in the lvarenergy register into a pulse output can be expressed in terms of impulses/ var h and varh /lsb. imp/lsb = nominal expected ib varcf varcf lsbvarh varhimp )( / / = (73) varcf ib ( expected ) = )sin( s/h3600 )/( ? b nominal ivvarhimpt varconstan (74) varcf ib ( nominal ) = period timeon accumulati period lvarenergy ib (s) hz50 (75) where the accumulation time is calculated from equation 37. the line period can be determined from the period register according to equation 38. then var can be determined from the lvarenergy register value: var h = period period lsbvarh lvarenergy ib hz 50 / (76) var = period timeon accumulati period lsbvarh lvarenergy ib (s) s/h3600/ hz50 (77) the period 50 hz / period factor in the preceding var equations is the correction factor for the 1/f frequency attenuation of the low-pass filter. the period 50 hz term refers to the line period at calibration and could represent a frequency other than 50 hz. clkin frequency in this data sheet, the characteristics of the ade7753 are shown when clkin frequency is equal to 3.579545 mhz. however, the ade7753 is designed to have the same accuracy at any clkin frequency within the specified range. if the clkin frequency is not 3.579545 mhz, various timing and filter characteristics need to be redefined with the new clkin frequency. for example, the cutoff frequencies of all digital filters such as lpf1, lpf2, or hpf1, shift in proportion to the change in clkin frequency according to the following equation: mhz frequency clkin frequency original frequency new 579545.3 = (78) the change of clkin frequency does not affect the timing characteristics of the serial interface because the data transfer is synchronized with serial clock signal (sclk). but one needs to observe the read/write timing of the serial data transfersee the ade7753 timing characteristics in tabl e 2 . table 11 lists various timing changes that are affected by clkin frequency. table 11. frequency dependencies of the ade7753 parameters parameter clkin dependency nyquist frequency for ch 1 and ch 2 adcs clkin/8 phcal resolution (seconds per lsb) 4/clkin active energy register update rate (hz) clkin/4 waveform sampling rate (per second) wavsel 1,0 = 0 0 clkin/128 0 1 clkin/256 1 0 clkin/512 1 1 clkin/1024 maximum zxtout period 524,288/clkin suspending ade7753 functionality the analog and the digital circuit can be suspended separately. the analog portion of the ade7753 can be suspended by setting the asuspend bit (bit 4) of the mode register to logic high see the mode register (0x9) section. in suspend mode, all wave- form samples from the adcs are set to 0. the digital circuitry can be halted by stopping the clkin input and maintaining a logic high or low on the clkin pin. the ade7753 can be reactivated by restoring the clkin input and setting the asuspend bit to logic low. checksum register the ade7753 has a checksum register (checksum[5:0]) to ensure the data bits received in the last serial read operation are not corrupted. the 6-bit checksum register is reset before the first bit (msb of the register to be read) is put on the dout pin. during a serial read operat ion, when each data bit becomes available on the rising edge of sclk, the bit is added to the checksum register. in the end of the serial read operation, the content of the checksum register is equal to the sum of all ones in the register previously read. using the checksum register, the user can determine if an error has occurred during the last read operation. note that a read to the checksum register also generates a checksum of the checksum register itself. content of register (n-bytes) checksum register addr: 0x3e + + dout 02875-0-077 figure 88. checksum register for serial interface read
ade7753 rev. c | page 49 of 60 ade7753 serial interface all ade7753 functionality is accessible via several on-chip registerssee figure 89 . the contents of these registers can be updated or read using the on-chip serial interface. after power- on or toggling the reset pin low or a falling edge on cs , the ade7753 is placed in communications mode. in communica- tions mode, the ade7753 expects a write to its communications register. the data written to the communications register determines whether the next data transfer operation is a read or a write and also which register is accessed. therefore all data transfer operations with the ade7753, whether a read or a write, must begin with a write to the communications register. communications register in out in out in out in out in out register 1 register 2 register 3 register n?1 register n register address decode din dout 02875-0-078 figure 89. addressing ade7753 regist ers via the communications register the communications register is an 8-bit wide register. the msb determines whether the next data transfer operation is a read or a write. the six lsbs contain the address of the register to be accessedsee the communications register section for a more detailed description. figure 90 and figure 91 show the data transfer sequences for a read and write operation, respectively. on completion of a data transfer (read or write), the ade7753 once again enters communications mode. a data transfer is complete when the lsb of the ade7753 register being addressed (for a write or a read) is transferred to or from the ade7753. multibyte communications register write din sclk cs dou t read data address 00 02875-0-079 figure 90. reading data from the ade7753 via the serial interface communications register write din sclk cs address 01 02875-0-080 multibyte read data figure 91. writing data to the ade7753 via the serial interface the serial interface of the ade7753 is made up of four signals: sclk, din, dout, and cs . the serial clock for a data transfer is applied at the sclk logic input. this logic input has a schmitt-trigger input structure that allows slow rising (and falling) clock edges to be used. all data transfer operations are synchronized to the serial clock. data is shifted into the ade7753 at the din logic input on the falling edge of sclk. data is shifted out of the ade7753 at the dout logic output on a rising edge of sclk. the cs logic input is the chip-select input. this input is used when multiple devices share the serial bus. a falling edge on cs also resets the serial interface and places the ade7753 into communications mode. the cs input should be driven low for the entire data transfer operation. bringing cs high during a data transfer operation aborts the transfer and places the serial bus in a high impedance state. the cs logic input can be tied low if the ade7753 is the only device on the serial bus. however, with cs tied low, all initiated data transfer operations must be fully completed, i.e., the lsb of each register must be transferred because there is no other way of bringing the ade7753 back into communications mode without resetting the entire device by using reset .
ade7753 rev. c | page 50 of 60 ade7753 serial write operation the serial write sequence takes place as follows. with the ade7753 in communications mode (i.e., the cs input logic low), a write to the communications register first takes place. the msb of this byte transfer is a 1, indicating that the data transfer operation is a write. the lsbs of this byte contain the address of the register to be written to. the ade7753 starts shifting in the register data on the next falling edge of sclk. all remaining bits of register data are shifted in on the falling edge of subsequent sclk pulsessee . as explained earlier, the data write is initiated by a write to the communications register followed by the data. during a data write operation to the ade7753, data is transferred to all on-chip registers one byte at a time. after a byte is transferred into the serial port, there is a finite time before it is transferred to one of the ade7753 on-chip registers. although another byte transfer to the serial port can start while the previous byte is being transferred to an on-chip register, this second byte transfer figure 92 should not finish until at least 4 s after the end of the previous byte transfer. this functionality is expressed in the timing specification t 6 see figure 92 . if a write operation is aborted during a byte transfer ( cs brought high), then that byte cannot be written to the destination register. destination registers can be up to 3 bytes widesee the ade7753 register description tables. therefore the first byte shifted into the serial port at din is transferred to the msb (most significant byte) of the destination register. if, for example, the addressed register is 12 bits wide, a 2-byte data transfer must take place. the data is always assumed to be right justified, therefore in this case, the four msbs of the first byte would be ignored and the four lsbs of the first byte written to the ade7753 would be the four msbs of the 12-bit word. figure 93 illustrates this example. din scl k cs t 2 t 3 t 1 t 4 t 5 t 7 t 6 t 8 command byte most significant byte least significant byte 10 a4a5 a3 a2 a1 a0 db7 db0 db7 db0 t 7 02875-0-081 figure 92. serial interface write timing scl k din x x x x db11 db10 db9 db8 db7 db6 db5 db4 db3 db2 db1 db0 most significant byte least significant byte 02875-0-082 figure 93. 12-bit serial write operation
ade7753 rev. c | page 51 of 60 ade7753 serial read operation during a data read operation from the ade7753, data is shifted out at the dout logic output on the rising edge of sclk. as is the case with the data write operation, a data read must be preceded with a write to the communications register. with the ade7753 in communications mode (i.e., cs logic low), an 8-bit write to the communications register first takes place. the msb of this byte transfer is a 0, indicating that the next data transfer operation is a read. the lsbs of this byte contain the address of the register that is to be read. the ade7753 starts shifting out of the register data on the next rising edge of sclksee . at this point, the dout logic output leaves its high impedance state and starts driving the data bus. all remaining bits of register data are shifted out on subsequent sclk rising edges. the serial interface also enters communications mode again as soon as the read has been completed. at this point, the dout logic output enters a high impedance state on the falling edge of the last sclk pulse. the read operation can be aborted by bringing the figure 94 cs logic input high before the data transfer is complete. the dout output enters a high impedance state on the rising edge of cs . when an ade7753 register is addressed for a read operation, the entire contents of that register are transferred to the serial port. this allows the ade7753 to modify its on-chip registers without the risk of corrupting data during a multibyte transfer. note that when a read operation follows a write operation, the read command (i.e., write to communications register) should not happen for at least 4 s after the end of the write operation. if the read command is sent within 4 s of the write operation, the last byte of the write operation could be lost. this timing constraint is given as timing specification t 9 . sclk cs t 1 t 10 t 13 0 0 a4a5 a3 a2 a1 a0 db0 db7 db0 db7 din dout t 11 t 11 t 12 command byte most significant byte least significant byte t 9 02875-0-083 figure 94. serial interface read timing
ade7753 rev. c | page 52 of 60 ade7753 registers table 12. summary of registers by address address name r/w no. bits default type 1 description 0x01 waveform r 24 0x0 s waveform register. this read-only register contains the sampled waveform data from either channel 1, channel 2, or the active power signal. the data source and the length of the waveform registers are selected by data bits 14 and 13 in the mode registersee the channel 1 sampling and channel 2 sampling sections. 0x02 aenergy r 24 0x0 s active energy register. active power is accumulated (integrated) over time in this 24-bit, read-only registersee the energy calculation section. 0x03 raenergy r 24 0x0 s same as the active energy register except that the register is reset to 0 following a read operation. 0x04 laenergy r 24 0x0 s line accumulation active energy register. the instantaneous active power is accumulated in this read-only register over the linecyc number of half line cycles. 0x05 vaenergy r 24 0x0 u apparent energy register. apparent power is accumulated over time in this read-only register. 0x06 rvaenergy r 24 0x0 u same as the vaenergy register except that the register is reset to 0 following a read operation. 0x07 lvaenergy r 24 0x0 u line accumulation appare nt energy register. the instantaneous real power is accumulated in this read-only register over the linecyc number of half line cycles. 0x08 lvarenergy r 24 0x0 s line accumulation reactive energy register. the instantaneous reactive power is accumulated in this read-only register over the linecyc number of half line cycles. 0x09 mode r/w 16 0x000c u mode register. this is a 16-bit register through which most of the ade7753 functionality is accessed. signal sa mple rates, filter enabling, and calibration modes are selected by writing to this register. the contents can be read at any timesee the mode register (0x9) section. 0x0a irqen r/w 16 0x40 u interrupt enable register. ade7753 interr upts can be deactivated at any time by setting the corresponding bit in this 16- bit enable register to logic 0. the status register continues to register an interrupt event even if disabled. however, the irq output is not activatedsee the section. ade7753 interrupts 0x0b status r 16 0x0 u interrupt status register. this is an 16-bit read-only register. the status register contains information regarding the source of ade7753 interruptsthe see ade7753 interrupts section. 0x0c rststatus r 16 0x0 u same as the interrupt status register except that the register contents are reset to 0 (all flags cleared) after a read operation. 0x0d ch1os r/w 8 0x00 s * channel 1 offset adjust. bit 6 is not used. writing to bits 0 to 5 allows offsets on channel 1 to be removedsee the analog inputs and ch1os register (0x0d) sections. writing a logic 1 to the msb of this register enables the digital integrator on channel 1, a logic 0 disables the integrator. the default value of this bit is 0. 0x0e ch2os r/w 8 0x0 s * channel 2 offset adjust. bits 6 and 7 are not used. writing to bits 0 to 5 of this register allows any offsets on channel 2 to be removedsee the analog inputs section. note that the ch2os register is inverted. to apply a positive offset, a negative number is written to this register. 0x0f gain r/w 8 0x0 u pga gain adjust. this 8-bit register is used to adjust the gain selection for the pga in channels 1 and 2see the analog inputs section. 0x10 phcal r/w 6 0x0d s phase calibration register. the phase relationship between channel 1 and 2 can be adjusted by writing to this 6-bit register. the valid content of this twos compliment register is between 0x 1d to 0x21. at a line frequency of 60 hz, this is a range from C2.06 to +0.7?see the phase compensation section. 0x11 apos r/w 16 0x0 s active power offset correction. this 16-bit register allows small offsets in the active power calculation to be removedsee the active power calculation section.
ade7753 rev. c | page 53 of 60 address name r/w no. bits default type 1 description 0x12 wgain r/w 12 0x0 s power gain adjust. this is a 12-bit register. the active power calculation can be calibrated by writing to this register. the calibration range is 50% of the nominal full-scale active power. th e resolution of the gain adjust is 0.0244%/lsb see the calibrating an energy meter based on the ade7753 section. 0x13 wdiv r/w 8 0x0 u active energy divider register. the internal active energy register is divided by the value of this register before being stored in the aenergy register. 0x14 cfnum r/w 12 0x3f u cf frequency divider numerator register. the output frequency on the cf pin is adjusted by writing to this 12-bit read/write registersee the energy- to-frequency conversion section. 0x15 cfden r/w 12 0x3f u cf frequency divider denominator register. the output frequency on the cf pin is adjusted by writing to this 12-bit read/write registersee the energy-to-frequency conversion section. 0x16 irms r 24 0x0 u channel 1 rms value (current channel). 0x17 vrms r 24 0x0 u channel 2 rms value (voltage channel). 0x18 irmsos r/w 12 0x0 s channel 1 rms offset correction register. 0x19 vrmsos r/w 12 0x0 s channel 2 rms offset correction register. 0x1a vagain r/w 12 0x0 s apparent gain register. apparent power calculation can be calibrated by writing to this register. the calibration range is 50% of the nominal full- scale real power. the resolution of the gain adjust is 0.02444%/lsb. 0x1b vadiv r/w 8 0x0 u apparent energy divider register. the internal apparent energy register is divided by the value of this register before being stored in the vaenergy register. 0x1c linecyc r/w 16 0xffff u line cycle energy accumulation mode line-cycle register. this 16-bit register is used during line cycle energy accumulation mode to set the number of half line cycles for energy accumulationsee the line cycle energy accumulation mode section. 0x1d zxtout r/w 12 0xfff u zero-crossing timeout. if no zero crossings are detected on channel 2 within a time period specified by this 12-bit register, the interrupt request line ( irq ) is activatedsee the section. zero-crossing detection 0x1e sagcyc r/w 8 0xff u sag line cycle register. this 8-bit register specifies the number of consecutive line cycles the signal on channel 2 must be below saglvl before the sag output is activatedsee the line voltage sag detection section. 0x1f saglvl r/w 8 0x0 u sag voltage level. an 8-bit write to th is register determines at what peak signal level on channel 2 the sag pin becomes active. the signal must remain low for the number of cycles specified in the sagcyc register before the sag pin is activatedsee the section. line voltage sag detection 0x20 ipklvl r/w 8 0xff u channel 1 peak level threshold (current channel). this register sets the level of the current peak detection. if the channel 1 input exceeds this level, the pki flag in the status register is set. 0x21 vpklvl r/w 8 0xff u channel 2 peak level threshold (voltage channel). this register sets the level of the voltage peak detection. if the channel 2 input exceeds this level, the pkv flag in the status register is set. 0x22 ipeak r 24 0x0 u channel 1 peak register. the maximum input value of the current channel since the last read of the register is stored in this register. 0x23 rstipeak r 24 0x0 u same as channel 1 peak register except that the register contents are reset to 0 after read. 0x24 vpeak r 24 0x0 u channel 2 peak register. the maximum input value of the voltage channel since the last read of the register is stored in this register. 0x25 rstvpeak r 24 0x0 u same as channel 2 peak register except that the register contents are reset to 0 after a read. 0x26 temp r 8 0x0 s temperature register. this is an 8-bit register which contains the result of the latest temperature conversionsee the temperature measurement section.
ade7753 rev. c | page 54 of 60 address name r/w no. bits default type 1 description 0x27 period r 16 0x0 u period of the channel 2 (voltage channel) input estimated by zero- crossing processing. the msb of this register is always zero. 0x28C 0x3c reserved. 0x3d tmode r/w 8 C u test mode register. 0x3e chksum r 6 0x0 u checksum register. this 6-bit read-only register is equal to the sum of all the ones in the previous readsee the ade7753 serial read operation section. 0x3f dierev r 8 C u die revision register. this 8-bit read-only register contains the revision number of the silicon. 1 type decoder: u = unsigned, s = signed by twos complement method, and s * = signed by sign magnitude method.
ade7753 rev. c | page 55 of 60 ade7753 register descriptions all ade7753 functionality is accessed via the on-chip registers. each register is accessed by first writing to the communicatio ns register and then transferring the register data. a full description of the serial interface protocol is given in the ade7753 serial interface section. communications register the communications register is an 8-bit, write-only register which controls the serial data transfer between the ade7753 and th e host processor. all data transfer operations must begin with a write to the communications register. the data written to the communi cations register determines whether the next operation is a read or a write and which register is being accessed. tabl e 13 outlines the bit designations for the communications register. db7 db6 db5 db4 db3 db2 db1 db0 w/r 0 a5 a4 a3 a2 a1 a0 table 13. communications register bit location bit mnemonic description 0 to 5 a0 to a5 the six lsbs of the communications register specify the register for the data transfer operation. table 12 lists the address of each ade7753 on-chip register. 6 reserved this bit is unused and should be set to 0. 7 w/r when this bit is a logic 1, the data transfer operation immediately following the write to the communications register is interpreted as a write to the ade7753. when this bit is a logic 0, the data transfer operation immediately following the write to the communications register is interpreted as a read operation. mode register (0x09) the ade7753 functionality is configured by writing to the mode register. tabl e 14 describes the functionality of each bit in the register. table 14. mode register bit location bit mnemonic default value description 0 dishpf 0 hpf (high-pass filter) in channe l 1 is disabled when this bit is set. 1 dislpf2 0 lpf (low-pass filter) after the multipli er (lpf2) is disabled when this bit is set. 2 discf 1 frequency output cf is di sabled when this bit is set. 3 dissag 1 line voltage sag detection is disabled when this bit is set. 4 asuspend 0 by setting this bit to logic 1, both ade7753 a/d converters can be turned off. in normal operation, this bit should be left at logic 0. all digital functionality can be stopped by suspending the clock signal at clkin pin. 5 tempsel 0 temperature conversion starts when this bit is se t to 1. this bit is automatically reset to 0 when the temperature conversion is finished. 6 swrst 0 software chip reset. a data transfer should not take place to the ade7753 for at least 18 s after a software reset. 7 cycmode 0 setting this bit to logic 1 places the chip into line cycle energy accumulation mode. 8 disch1 0 adc 1 (channel 1) inputs are internally shorted together. 9 disch2 0 adc 2 (channel 2) inputs are internally shorted together. 10 swap 0 by setting this bit to logic 1 the analog in puts v2p and v2n are connected to adc 1 and the analog inputs v1p and v1n are connected to adc 2. 12, 11 dtrt1, 0 00 these bits are used to select the waveform register update rate. dtrt 1 dtrt0 update rate 0 0 27.9 ksps (clkin/128) 0 1 14 ksps (clkin/256) 1 0 7 ksps (clkin/512) 1 1 3.5 ksps (clkin/1024)
ade7753 rev. c | page 56 of 60 bit location bit mnemonic default value description 14, 13 wavsel1, 0 00 these bits are used to select the so urce of the sampled data for the waveform register. wavsel1, 0 length source 0 0 24 bits active power signal (output of lpf2) 0 1 reserved 1 0 24 bits channel 1 1 1 24 bits channel 2 15 poam 0 writing logic 1 to this bit allows only positive active power to be accumulated in the ade7753. 0000000000001100 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 addr: 0x09 swap (swap ch1 and ch2 adcs) dtrt (waveform samples output data rate) 00 = 27.9ksps (clkin/128) 01 = 14.4ksps (clkin/256) 10 = 7.2ksps (clkin/512) 11 = 3.6ksps (clkin/1024) poam (positive only accumulation) wavsel (waveform selection for sample mode) 00 = lpf2 01 = reserved 10 = ch1 11 = ch2 dishpf (disable hpf1 in channel 1) dislpf2 (disable lpf2 after multiplier) discf (disable frequency output cf) dissag (disable sag output) asuspend (suspend ch1 and ch2 adcs) tempsel (start temperature sensing) swrst (software chip reset) cycmode (line cycle energy accumulation mode) disch2 (short the analog inputs on channel 2) disch1 (short the analog inputs on channel 1) note: register contents show power-on defaults 02875-0-084 figure 95. mode register
ade7753 rev. c | page 57 of 60 interrupt status register (0x0b), rese t interrupt status register (0x0c), interrupt enable register (0x0a) the status register is used by the mcu to determine the source of an interrupt request ( irq ). when an interrupt event occurs in the ade7753, the corresponding flag in the interrupt status register is set to logic high. if the enable bit for this flag is logic 1 in the interrupt enable register, the irq logic output goes active low. when the mcu services the interrupt, it must first carry out a read from the interrupt status register to determine the source of the interrupt. table 15. interrupt status register, reset interrupt status register, and in terrupt enable register bit location interrupt flag description 0 aehf indicates that an interrupt occurred because the ac tive energy register, aenergy, is more than half full. 1 sag indicates that an interrupt was caused by a sag on the line voltage. 2 cycend indicates the end of energy accumulation over an integer number of half line cycles as defined by the content of the linecyc registersee the line cycle energy accumulation mode section. 3 wsmp indicates that new data is present in the waveform register. 4 zx this status bit is set to logic 0 on the rising and falling edge of the the voltage waveform. see the zero-crossing detection section. 5 temp indicates that a temperature conversion result is available in the temperature register. 6 reset indicates the end of a reset (for both software or hardware reset). the corresponding enable bit has no function in the interrupt enable register, i.e., this st atus bit is set at the end of a reset, but it cannot be enabled to cause an interrupt. 7 aeof indicates that the active energy register has overflowed. 8 pkv indicates that waveform sample from channel 2 has exceeded the vpklvl value. 9 pki indicates that waveform sample from channel 1 has exceeded the ipklvl value. a vaehf indicates that an interrupt occurred because the ac tive energy register, vaenergy, is more than half full. b vaeof indicates that the apparent energy register has overflowed. c zxto indicates that an interrupt was caused by a missing zero crossing on the line voltage for the specified number of line cyclessee the zero-crossing timeout section. d ppos indicates that the power has gone from negative to positive. e pneg indicates that the power has gone from positive to negative. f reserved reserved. 00000 0 0 000 0 00 00 0 8 97 4 5 62 30 1 15 14 13 12 11 10 aehf (active energy half-full) addr: 0x0a, 0x0b, 0x0c sag (sag online voltage) cycend (end of linecyc half line cycles) wsmp (waveform samples data ready) zx (zero crossing) templ (temperature data ready) reset (end of software/hardware reset) aeof (active energy register overflow) vaehf (vaenergy is half-full) ppos (power negative to positive) reserved pneg (power positive to negative) zxto (zero-crossing timeout) vaeof (vaenergy overflow) pk1 (channel 1 sample above ipklvl) pkv (channel 2 sample above vpklvl ) 02875-a-013 figure 96. interrupt status/interrupt enable register
ade7753 rev. c | page 58 of 60 ch1os register (0x0d) the ch1os register is an 8-bit, read/write enabled register. the msb of this register is used to switch on/off the digital inte grator in channel 1, and bits 0 to 5 indicates the amount of the offset correction in channel 1. table 16 summarizes the function of this register. table 16. ch1os register bit location bit mnemonic description 0 to 5 offset the six lsbs of the ch1os register control the amount of dc offset correction in channel 1 adc. the 6-bit offset correction is sign and magnitude coded. bits 0 to 4 indicate the magnitude of the offset correction. bit 5 shows the sign of the offset correction. a 0 in bit 5 means the offset correction is positive and a 1 indicates the offset correction is negative. 6 not used this bit is unused. 7 integrator this bit is used to activate the digital integrator on channel 1. the digital integrator is switched on by setting this bit. this bit is set to be 0 on default. digital integrator selection 1 = enable 0 = disable not used 00000000 76543210 addr: 0x0d sign and magnitude coded offset correction bits 02875-0-086 figure 97. channel 1 offset register
ade7753 rev. c | page 59 of 60 outline dimensions compliant to jedec standards mo-150-ae 060106-a 20 11 10 1 7.50 7.20 6.90 8.20 7.80 7.40 5.60 5.30 5.00 seating plane 0.05 min 0.65 bsc 2.00 max 0.38 0.22 coplanarity 0.10 1.85 1.75 1.65 0.25 0.09 0.95 0.75 0.55 8 4 0 figure 98. 20-lead shrink small outline package [ssop] (rs-20) dimensions shown in millimeters ordering guide model 1 temperature range package description package option ade7753ars ?40c to +85c 20-lead shrink small outline package [ssop] rs-20 ade7753arsrl ?40c to +85c 20-lead shri nk small outline package [ssop] rs-20 ADE7753ARSZ ?40c to +85c 20-lead shrink small outline package [ssop] rs-20 ADE7753ARSZrl ?40c to +85c 20-lead shri nk small outline package [ssop] rs-20 eval-ade7753zeb evaluation board 1 z = rohs compliant part.
ade7753 rev. c | page 60 of 60 notes ?2003C2010 analog devices, inc. all rights reserved. trademarks and registered trademarks are the prop erty of their respective owners. d02875-0-1/10(c)


▲Up To Search▲   

 
Price & Availability of ADE7753ARSZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X